Investigating radiation effects on LSF0102 level shifters
We present the results of a Total Ionizing Dose (TID) test on Texas Instruments LSF0102 level shifters irradiated with 60Co gamma rays up to a total dose of 20 kGy. Non-monotonic variations were observed in the supply current, high-level output voltage, and output characteristics as a function of dose. Worst-case scenario in terms of highest supply current and lowest high-level output voltage occurs at a specific critical dose. This behavior should be carefully considered when evaluating such devices for use in environments with high radiation levels.
Publication Details
- Journal
- Springer Link (Chiba Institute of Technology)
- Published
- 2025-11-06
- DOI
- https://doi.org/10.1051/epjconf/202533810003/pdf
- Primary Topic
- Radiation Effects in Electronics
- Type
- article
- Field-Weighted Citation Impact
- 0.00