Optimizing Coagulant-FlocculantComposition to ReduceDissolved Zinc inElectroplating Effluent

Electroplating liquid waste creates toxic metal-organic complexes, posing a considerable environmental hazard. The primary problem is determining the most efficient and ecologically beneficial approach for processing this waste. One promising approach is the coagulant-flocculant procedure. This study focused on establishing the optimum combination of coagulant and flocculant to decrease Zn heavy metal liquid waste. The research involved experimenting with various compositions of pH, PAC (Poly Aluminium Chloride), and anionic polymers. The jartest equipment was applied to analyze changes in Total Dissolved Solid (TDS), Zn levels, and turbidity. The findings revealed that the optimal conditions were obtained at pH 8 with 40 ppm coagulant and 0.1 ppm flocculant. TDS increased by 11.05% (from 1262 ppm to 1401 ppm), whereas turbidity and Zn levels fell by 98.17% (from 54 to 1 NTU) and 98.38% (from 9.8 ppm to 0.16 ppm), respectively. These results underline the suitability of this composition for effectively treating increasing volumes of electroplating waste.

Institutions

Publication Details

Journal
Environmental Research Engineering and Management
Published
2025-10-08
DOI
https://doi.org/10.5755/j01.erem.81.3.39457
Primary Topic
Coagulation and Flocculation Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing Coagulant-FlocculantComposition to ReduceDissolved Zinc inElectroplating Effluent

Environmental Research Engineering and Management
Coagulation and Flocculation Studies
article

Optimizing Coagulant-FlocculantComposition to ReduceDissolved Zinc inElectroplating Effluent

article en

Abstract

Electroplating liquid waste creates toxic metal-organic complexes, posing a considerable environmental hazard. The primary problem is determining the most efficient and ecologically beneficial approach for processing this waste. One promising approach is the coagulant-flocculant procedure. This study focused on establishing the optimum combination of coagulant and flocculant to decrease Zn heavy metal liquid waste. The research involved experimenting with various compositions of pH, PAC (Poly Aluminium Chloride), and anionic polymers. The jartest equipment was applied to analyze changes in Total Dissolved Solid (TDS), Zn levels, and turbidity. The findings revealed that the optimal conditions were obtained at pH 8 with 40 ppm coagulant and 0.1 ppm flocculant. TDS increased by 11.05% (from 1262 ppm to 1401 ppm), whereas turbidity and Zn levels fell by 98.17% (from 54 to 1 NTU) and 98.38% (from 9.8 ppm to 0.16 ppm), respectively. These results underline the suitability of this composition for effectively treating increasing volumes of electroplating waste.

Environmental Research Engineering and ManagementVol. 81(3)
Reinhardt University (US), Jenderal Soedirman University (ID)
Openalex Percentile: Top 40%
Coagulation and Flocculation Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Optimizing Coagulant-FlocculantComposition to ReduceDissolved Zinc inElectroplating Effluent · Environmental Research Engineering and Management (2025) | TGRS Research Map | TGRS