S4540 Listen to Your Gut: A Case Report Highlighting the Risk of Caustic Injuries From Ingestion of Wearable Technologies

Introduction: Lithium-ion batteries are the battery of choice for wearable technologies for their compact size with powerful charge. Due to its popularity in technology, caustic injuries secondary to lithium ingestion continue to be a major problem with 855 lithium battery ingestions reported to the National Poison Data System in 2023. This case report discusses the importance of considering the internal components of wearable technologies when managing foreign body ingestions. Case Description/Methods: A 28-year-old man with history of autism spectrum disorder, recurrent suicidal ideations, and schizoaffective disorder with command auditory hallucinations presented overnight after swallowing reported Bluetooth earbuds. He previously underwent ileostomy, partial colectomy, and reversal anastomosis after ingesting batteries. On presentation, he was endorsing epigastric and left upper quadrant pain. Initial abdominal x-ray showed mobile radio-opaque foreign bodies in the gastric lumen. Repeat abdominal x-ray 5 hours later showed the foreign bodies with a possible wire connection in mid-abdomen. Urgent enteroscopy the next day did not show any foreign bodies in the stomach, duodenum or proximal jejunum. Patient endorsed worsening umbilical abdominal pain. Computed tomography Abdomen and Pelvis the same evening showed 2 metallic ovoid structures at the transverse and proximal descending colon respectively. Flexible sigmoidoscopy was performed the following day and found 1 earbud covered in stool with exposed wires, another earbud covered in stool with approximately 5 cm wire attached, and wire fragments which were all retrieved. Discussion: Caustic injuries from ingestion of lithium batteries are well-documented in literature; however, wearable technologies are becoming increasingly popular. This includes smart rings, earrings, watches, glasses, and Bluetooth earbuds which are small enough to ingest and include lithium batteries. Prompt recognition of wearable technologies when managing foreign body ingestions is important to prevent delays in appropriate interventions and avoid potential complications.

Publication Details

Journal
The American Journal of Gastroenterology
Published
2025-10-01
DOI
https://doi.org/10.14309/01.ajg.0001145620.57134.f0
Primary Topic
Foreign Body Medical Cases
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

S4540 Listen to Your Gut: A Case Report Highlighting the Risk of Caustic Injuries From Ingestion of Wearable Technologies

The American Journal of Gastroenterology
Foreign Body Medical Cases
article

S4540 Listen to Your Gut: A Case Report Highlighting the Risk of Caustic Injuries From Ingestion of Wearable Technologies

article en

Abstract

Introduction: Lithium-ion batteries are the battery of choice for wearable technologies for their compact size with powerful charge. Due to its popularity in technology, caustic injuries secondary to lithium ingestion continue to be a major problem with 855 lithium battery ingestions reported to the National Poison Data System in 2023. This case report discusses the importance of considering the internal components of wearable technologies when managing foreign body ingestions. Case Description/Methods: A 28-year-old man with history of autism spectrum disorder, recurrent suicidal ideations, and schizoaffective disorder with command auditory hallucinations presented overnight after swallowing reported Bluetooth earbuds. He previously underwent ileostomy, partial colectomy, and reversal anastomosis after ingesting batteries. On presentation, he was endorsing epigastric and left upper quadrant pain. Initial abdominal x-ray showed mobile radio-opaque foreign bodies in the gastric lumen. Repeat abdominal x-ray 5 hours later showed the foreign bodies with a possible wire connection in mid-abdomen. Urgent enteroscopy the next day did not show any foreign bodies in the stomach, duodenum or proximal jejunum. Patient endorsed worsening umbilical abdominal pain. Computed tomography Abdomen and Pelvis the same evening showed 2 metallic ovoid structures at the transverse and proximal descending colon respectively. Flexible sigmoidoscopy was performed the following day and found 1 earbud covered in stool with exposed wires, another earbud covered in stool with approximately 5 cm wire attached, and wire fragments which were all retrieved. Discussion: Caustic injuries from ingestion of lithium batteries are well-documented in literature; however, wearable technologies are becoming increasingly popular. This includes smart rings, earrings, watches, glasses, and Bluetooth earbuds which are small enough to ingest and include lithium batteries. Prompt recognition of wearable technologies when managing foreign body ingestions is important to prevent delays in appropriate interventions and avoid potential complications.

The American Journal of GastroenterologyVol. 120(10S2)
Good health and well-being
Openalex Percentile: Top 33%
Foreign Body Medical Cases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.