Photon energy reconstruction with the MEG II liquid xenon calorimeter
The MEG II experiment searches for a charged-lepton-flavour-violating μ → eε with the target sensitivity of 6×10−14. A liquid xenon calorimeter with VUV-sensitive photosensors measures photon position, timing, and energy. This paper concentrates on the precise photon energy reconstruction with the MEG II liquid xenon calorimeter. Since a muon beam rate is 3–5 × 107 s−1, multi-photon elimination analysis is performed using waveform analysis techniques such as a template waveform fit. As a result, background events in the energy range of 48–58 MeV were reduced by 34 %. The calibration of the energy scale of the calorimeter with several calibration sources is also discussed to achieve a high resolution of 1 .8 %.
Publication Details
- Journal
- Springer Link (Chiba Institute of Technology)
- Published
- 2025-03-07
- DOI
- https://doi.org/10.1051/epjconf/202532000030/pdf
- Primary Topic
- Dark Matter and Cosmic Phenomena
- Type
- article
- Field-Weighted Citation Impact
- 0.00