Estimation of the time of exposure from the differential fading of luminescent detectors

Containment and surveillance measures for unattended or remotely monitored items and areas serve to detect, timestamp, and thereby deter the illicit movement and trafficking of radioactive material in the interval between two successive inspections. This study explores the feasibility of a passive solution that does not rely on complex electronic components, thus mitigating common vulnerabilities of active instruments, including risks of tampering and unauthorised data access. The signal loss in luminescent materials – dependent on both time and temperature and previously investigated as a means of estimating the time of exposure – proved applicable in this safeguards-relevant context as well. The differential fading of peaks II and III of the glow curve of LiF:Mg,Cu,P (GR-200A), compared to the stable dosimetric peak IV, provided a means to timestamp the moment of irradiation with reasonable accuracy in the shortand medium-term after exposure. While the analysis primarily focused on the behaviour of individual crystals, the averaging of multiple responses was also explored for comparison, to assess its potential for reducing estimation error.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-11-06
DOI
https://doi.org/10.1051/epjconf/202533806011/pdf
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Estimation of the time of exposure from the differential fading of luminescent detectors

Springer Link (Chiba Institute of Technology)
Radiation Detection and Scintillator Technologies
article

Estimation of the time of exposure from the differential fading of luminescent detectors

article en

Abstract

Containment and surveillance measures for unattended or remotely monitored items and areas serve to detect, timestamp, and thereby deter the illicit movement and trafficking of radioactive material in the interval between two successive inspections. This study explores the feasibility of a passive solution that does not rely on complex electronic components, thus mitigating common vulnerabilities of active instruments, including risks of tampering and unauthorised data access. The signal loss in luminescent materials – dependent on both time and temperature and previously investigated as a means of estimating the time of exposure – proved applicable in this safeguards-relevant context as well. The differential fading of peaks II and III of the glow curve of LiF:Mg,Cu,P (GR-200A), compared to the stable dosimetric peak IV, provided a means to timestamp the moment of irradiation with reasonable accuracy in the shortand medium-term after exposure. While the analysis primarily focused on the behaviour of individual crystals, the averaging of multiple responses was also explored for comparison, to assess its potential for reducing estimation error.

Springer Link (Chiba Institute of Technology)
Gender equality
Openalex Percentile: Top 29%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.