Experimental and Simulation Analysis of IEQ and Energy Demand in an Office Building in Northern Greece

The present study aims to assess both the indoor environmental quality (IEQ) and the energy demand of an office building in Kozani, Western Macedonia, Greece. Thermal comfort was evaluated by analysing questionnaire responses and by applying both the Fanger and adaptive models, while CO2 concentration served as an index of indoor air quality (IAQ). Illuminance (lux) readings and acoustic measurements were also collected to assess the lighting and acoustic conditions, respectively. The IEQ assessment indicates that the Fanger model has limited applicability in naturally ventilated or mixed-mode spaces; CO2 concentrations fluctuated at low levels due to natural ventilation; and the acoustic and lighting indicators were within acceptable limits. A simulation study was conducted to assess the building’s energy consumption under different cooling and ventilation scenarios, as well as the impact of climate zone on cooling loads. The analysis shows that natural ventilation achieves greater reductions in cooling loads in climates with lower outdoor temperatures, and that the ventilation period is also critical for energy savings. Overall, the proposed approach combines experimental and computational tools and can be further developed into an integrated methodology to ensure occupant comfort and health at the lowest possible energy cost.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-11-26
DOI
https://doi.org/10.1051/e3sconf/202566901001/pdf
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental and Simulation Analysis of IEQ and Energy Demand in an Office Building in Northern Greece

Springer Link (Chiba Institute of Technology)
Building Energy and Comfort Optimization
article

Experimental and Simulation Analysis of IEQ and Energy Demand in an Office Building in Northern Greece

article en

Abstract

The present study aims to assess both the indoor environmental quality (IEQ) and the energy demand of an office building in Kozani, Western Macedonia, Greece. Thermal comfort was evaluated by analysing questionnaire responses and by applying both the Fanger and adaptive models, while CO2 concentration served as an index of indoor air quality (IAQ). Illuminance (lux) readings and acoustic measurements were also collected to assess the lighting and acoustic conditions, respectively. The IEQ assessment indicates that the Fanger model has limited applicability in naturally ventilated or mixed-mode spaces; CO2 concentrations fluctuated at low levels due to natural ventilation; and the acoustic and lighting indicators were within acceptable limits. A simulation study was conducted to assess the building’s energy consumption under different cooling and ventilation scenarios, as well as the impact of climate zone on cooling loads. The analysis shows that natural ventilation achieves greater reductions in cooling loads in climates with lower outdoor temperatures, and that the ventilation period is also critical for energy savings. Overall, the proposed approach combines experimental and computational tools and can be further developed into an integrated methodology to ensure occupant comfort and health at the lowest possible energy cost.

Springer Link (Chiba Institute of Technology)
Affordable and clean energy
Openalex Percentile: Top 44%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.