Per- and Polyfluoroalkyl Substances in Southern Ontario Drinking Water and Wastewater

The presence of 41 per- and polyfluorinated alkyl substances (PFAS) was investigated in raw and finished drinking water and in influent and effluent wastewater sampled from facilities in the Great Lakes Basin region of Southern Ontario, Canada (September–November 2023). Based on US Environmental Protection Agency Method 1633A, the method developed for analysis of these species demonstrates high sensitivity and recovery with limits of quantitation that range between 0.075 ng L–1 and 3.0 ng L–1. Linear chain PFAS with carboxylic acid and sulfonic acid groups were detected in finished water from all drinking water treatment plants (n = 6). Wastewater effluents (n = 2) had PFAS concentrations approximately 1 order of magnitude higher than those in finished drinking water samples and included several fluorotelomers and ether-linked species. Across all sites, 13 of the 41 PFAS were detected in drinking water and 21 in wastewater. Average sum of 25 PFAS in finished drinking water ranged between 8.69 and 14.0 ng L–1, well below Health Canada’s objective of 30 ng L–1. These results highlight the persistence of PFAS across treatment systems and suggest a potential feedback loop where wastewater effluents reintroduce PFAS into surface waters used as drinking water sources.

Institutions

Publication Details

Journal
ACS ES&T Water
Published
2025-12-09
DOI
https://doi.org/10.1021/acsestwater.5c01004
Primary Topic
Per- and polyfluoroalkyl substances research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Per- and Polyfluoroalkyl Substances in Southern Ontario Drinking Water and Wastewater

ACS ES&T Water
Per- and polyfluoroalkyl substances research
article

Per- and Polyfluoroalkyl Substances in Southern Ontario Drinking Water and Wastewater

article en

Abstract

The presence of 41 per- and polyfluorinated alkyl substances (PFAS) was investigated in raw and finished drinking water and in influent and effluent wastewater sampled from facilities in the Great Lakes Basin region of Southern Ontario, Canada (September–November 2023). Based on US Environmental Protection Agency Method 1633A, the method developed for analysis of these species demonstrates high sensitivity and recovery with limits of quantitation that range between 0.075 ng L–1 and 3.0 ng L–1. Linear chain PFAS with carboxylic acid and sulfonic acid groups were detected in finished water from all drinking water treatment plants (n = 6). Wastewater effluents (n = 2) had PFAS concentrations approximately 1 order of magnitude higher than those in finished drinking water samples and included several fluorotelomers and ether-linked species. Across all sites, 13 of the 41 PFAS were detected in drinking water and 21 in wastewater. Average sum of 25 PFAS in finished drinking water ranged between 8.69 and 14.0 ng L–1, well below Health Canada’s objective of 30 ng L–1. These results highlight the persistence of PFAS across treatment systems and suggest a potential feedback loop where wastewater effluents reintroduce PFAS into surface waters used as drinking water sources.

ACS ES&T WaterVol. 6(1)
Western University (CA), University of Waterloo (CA), Hong Kong Eye Hospital (CN), USP Technologies (United Kingdom) (GB), Block Engineering (United States) (US), Brown and Caldwell (United States) (US)
Clean water and sanitation
Openalex Percentile: Top 43%
Per- and polyfluoroalkyl substances research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.