Optimization Design of a Novel Passive Micromixer Using Response Surface Methodology

Biochips and microchemical systems utilize micromixers to mix various reactants in microscale environments effectively. The innovative microfluidic device is described. This study aims to enhance the Mixing Index (MI) by changing geometric parameters and inlet velocity. This micromixer consists of two unbalanced U-shaped channels connected by a chevron obstacle within a hexagonal mixing chamber, which promotes efficient fluid interaction. Numerical simulations are performed using the finite element-based COMSOL Multiphysics software, and the results are used to optimize the micromixer performance using Response Surface Methodology (RSM). It is found that the inlet velocity greatly affects the MI and pressure drop (Δp), whereas the angle between the inlets does not affect either of these parameters. For instance, MI increases from 80.85% to 94.52% when Uin is raised from 0.01 m/s to 1 m/s. In general, the suggested micromixer exhibits an MI higher than 80% for all ranges of the considered independent variables. Furthermore, two correlations for MI and Δp are provided by the RSM that can be used to maximize this micromixer's performance.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-05-01
DOI
https://doi.org/10.30492/ijcce.2025.2050131.6959
Primary Topic
Microfluidic and Capillary Electrophoresis Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization Design of a Novel Passive Micromixer Using Response Surface Methodology

SHILAP Revista de lepidopterología
Microfluidic and Capillary Electrophoresis Applications
article

Optimization Design of a Novel Passive Micromixer Using Response Surface Methodology

article en

Abstract

Biochips and microchemical systems utilize micromixers to mix various reactants in microscale environments effectively. The innovative microfluidic device is described. This study aims to enhance the Mixing Index (MI) by changing geometric parameters and inlet velocity. This micromixer consists of two unbalanced U-shaped channels connected by a chevron obstacle within a hexagonal mixing chamber, which promotes efficient fluid interaction. Numerical simulations are performed using the finite element-based COMSOL Multiphysics software, and the results are used to optimize the micromixer performance using Response Surface Methodology (RSM). It is found that the inlet velocity greatly affects the MI and pressure drop (Δp), whereas the angle between the inlets does not affect either of these parameters. For instance, MI increases from 80.85% to 94.52% when Uin is raised from 0.01 m/s to 1 m/s. In general, the suggested micromixer exhibits an MI higher than 80% for all ranges of the considered independent variables. Furthermore, two correlations for MI and Δp are provided by the RSM that can be used to maximize this micromixer's performance.

SHILAP Revista de lepidopterología
Chongqing Vocational Institute of Engineering (CN)
Affordable and clean energy
Openalex Percentile: Top 46%
Microfluidic and Capillary Electrophoresis Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.