Implementation and design non-linear controller for stand-alone generator

This article describes the implementation and design of a non-linear controller for a stand-alone generator which has a DC motor as a prime mover based on input-output feedback linearization (FL) technique. While in the grids-connected synchronous generator the attention is focused on the load angle as stability assessment, the speed and terminal voltage is the main effective state in stand-alone generators. Therefore, the FL robust control design method is utilized to truck the desired speed and terminal voltage. First, a non-linear mathematical model is derived for the synchronous generator with a dc motor as a prime mover then input-output FL is applied to this non-linear model to make it linear. The tracking control low of the linearized model is designed using a pole placement technique. For verifying the efficiency and performance of the system, several tests were conducted in the Matlab simulation with some experimental results. These results showed a high dynamic response to a large and fast load difference and zero steady-condition error.

Publication Details

Journal
Periodicals of Engineering and Natural Sciences (PEN)
Published
2025-12-05
DOI
https://doi.org/10.21533/pen.v8.i4.1425
Primary Topic
Power System Optimization and Stability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Implementation and design non-linear controller for stand-alone generator

Periodicals of Engineering and Natural Sciences (PEN)
Power System Optimization and Stability
article

Implementation and design non-linear controller for stand-alone generator

article en

Abstract

This article describes the implementation and design of a non-linear controller for a stand-alone generator which has a DC motor as a prime mover based on input-output feedback linearization (FL) technique. While in the grids-connected synchronous generator the attention is focused on the load angle as stability assessment, the speed and terminal voltage is the main effective state in stand-alone generators. Therefore, the FL robust control design method is utilized to truck the desired speed and terminal voltage. First, a non-linear mathematical model is derived for the synchronous generator with a dc motor as a prime mover then input-output FL is applied to this non-linear model to make it linear. The tracking control low of the linearized model is designed using a pole placement technique. For verifying the efficiency and performance of the system, several tests were conducted in the Matlab simulation with some experimental results. These results showed a high dynamic response to a large and fast load difference and zero steady-condition error.

Periodicals of Engineering and Natural Sciences (PEN)Vol. 8(4)
Openalex Percentile: Top 45%
Power System Optimization and Stability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.