Estimation of Human Occupancy in Enclosed Spaces Using CO

This study investigates the estimation of human occupancy in enclosed indoor spaces using CO2 concentration data obtained from a low-cost sensor. An experimental campaign was conducted in a naturally ventilated university classroom, where CO2 levels and the number of occupants were recorded under controlled conditions. Statistical analysis, including linear regression and correlation methods, confirmed a strong positive relationship between occupancy and CO2 accumulation. The selected NDIR sensor (MH-Z16), integrated with an ESP32-based microcontroller, demonstrated sufficient sensitivity and stability for real-time data acquisition. The results validate the use of CO2 concentration as a reliable indirect indicator of human presence, particularly under standardized conditions with minimal external disturbances. The proposed approach offers a cost-effective and scalable solution for demand-controlled ventilation (DCV) in smart building applications, contributing to energy-efficient HVAC control and proactive indoor air quality and workplace safety management.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-11-21
DOI
https://doi.org/10.1051/e3sconf/202566701008/pdf
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Estimation of Human Occupancy in Enclosed Spaces Using CO

Springer Link (Chiba Institute of Technology)
Indoor Air Quality and Microbial Exposure
article

Estimation of Human Occupancy in Enclosed Spaces Using CO

article en

Abstract

This study investigates the estimation of human occupancy in enclosed indoor spaces using CO2 concentration data obtained from a low-cost sensor. An experimental campaign was conducted in a naturally ventilated university classroom, where CO2 levels and the number of occupants were recorded under controlled conditions. Statistical analysis, including linear regression and correlation methods, confirmed a strong positive relationship between occupancy and CO2 accumulation. The selected NDIR sensor (MH-Z16), integrated with an ESP32-based microcontroller, demonstrated sufficient sensitivity and stability for real-time data acquisition. The results validate the use of CO2 concentration as a reliable indirect indicator of human presence, particularly under standardized conditions with minimal external disturbances. The proposed approach offers a cost-effective and scalable solution for demand-controlled ventilation (DCV) in smart building applications, contributing to energy-efficient HVAC control and proactive indoor air quality and workplace safety management.

Springer Link (Chiba Institute of Technology)
Affordable and clean energy
Openalex Percentile: Top 37%
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Estimation of Human Occupancy in Enclosed Spaces Using CO · Springer Link (Chiba Institute of Technology) (2025) | TGRS Research Map | TGRS