Smoke Management in Tunnels with Longitudinal Ventilation System: An Experimental and Numerical Study

The ventilation system in tunnels serves dual roles, providing fresh air for comfort in normal conditions and managing smoke during emergencies. It maintains air quality for a safe environment in routine operations, safeguarding occupants. In emergencies, it crucially aids in smoke control, ensuring safety for rescue efforts and limiting fire spread. Regular tests are essential to validate safety systems, a prerequisite for tunnel usage approval. These tests typically involve fire and smoke assessments, verifying control and evacuation systems. Compliance ensures system efficacy, public safety, and risk mitigation through continuous improvement, enhancing overall tunnel safety and reliability. The current study experimentally analyzed the performance and behavior of the longitudinal ventilation system and related sub-systems in hot smoke control and toxic gas management through a standard fire test. Based on the test results and experimental data, a suitable numerical simulation model was developed to predict the behavior of the ventilation system in larger fires as well. The numerical and experimental results of this study indicate that a properly functioning ventilation system can lead to the creation of a safe and smoke-free environment on both sides of a fire. This effect is more noticeable in small fires where the fire's heat release rate is low and the tunnel cross-section is relatively large. In such scenarios, smoke tends to gather at higher levels during the initial stages of the fire, with only a small amount descending to lower levels. However, in cases of high-intensity fires, the situation changes significantly, and smoke settles, particularly downstream, on the tunnel floor after a certain period of time. The presence or absence of traffic was also observed to affect the quality of smoke dispersion and propagation. Additionally, the findings of this study can assist emergency fire response teams in managing safety within tunnels under diverse circumstances.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-03-01
DOI
https://doi.org/10.30492/ijcce.2024.2041913.6813
Primary Topic
Fire dynamics and safety research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Smoke Management in Tunnels with Longitudinal Ventilation System: An Experimental and Numerical Study

SHILAP Revista de lepidopterología
Fire dynamics and safety research
article

Smoke Management in Tunnels with Longitudinal Ventilation System: An Experimental and Numerical Study

article en

Abstract

The ventilation system in tunnels serves dual roles, providing fresh air for comfort in normal conditions and managing smoke during emergencies. It maintains air quality for a safe environment in routine operations, safeguarding occupants. In emergencies, it crucially aids in smoke control, ensuring safety for rescue efforts and limiting fire spread. Regular tests are essential to validate safety systems, a prerequisite for tunnel usage approval. These tests typically involve fire and smoke assessments, verifying control and evacuation systems. Compliance ensures system efficacy, public safety, and risk mitigation through continuous improvement, enhancing overall tunnel safety and reliability. The current study experimentally analyzed the performance and behavior of the longitudinal ventilation system and related sub-systems in hot smoke control and toxic gas management through a standard fire test. Based on the test results and experimental data, a suitable numerical simulation model was developed to predict the behavior of the ventilation system in larger fires as well. The numerical and experimental results of this study indicate that a properly functioning ventilation system can lead to the creation of a safe and smoke-free environment on both sides of a fire. This effect is more noticeable in small fires where the fire's heat release rate is low and the tunnel cross-section is relatively large. In such scenarios, smoke tends to gather at higher levels during the initial stages of the fire, with only a small amount descending to lower levels. However, in cases of high-intensity fires, the situation changes significantly, and smoke settles, particularly downstream, on the tunnel floor after a certain period of time. The presence or absence of traffic was also observed to affect the quality of smoke dispersion and propagation. Additionally, the findings of this study can assist emergency fire response teams in managing safety within tunnels under diverse circumstances.

SHILAP Revista de lepidopterología
Islamic Azad University Semnan (IR)
Good health and well-being
Openalex Percentile: Top 40%
Fire dynamics and safety research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.