An Experimental Study of the Application of Cooling Water in Taking Heat from a Thermoelectric Cooler Used in Extracting Water from Humid Air

Humid air is one of the rich sources of water, especially in desert areas. One of the ways to extract water from humid air is to cool it down to a dew point in order to condense and collect water. This research applied a thermoelectric cooler for harvesting water from humid air. Cooling water was used to reject heat from the hot side of the thermoelectric. The effect of some parameters, such as the temperature, velocity, and humidity of the inlet air as well as the cooling water temperature, was investigated experimentally. The results showed that increasing the inlet air humidity and temperature increases the water collected. At a relative humidity of 20% and an air temperature of 35 oC, the maximum amount of water at an inlet air velocity of 1 m/s was equal to about 43 mL. Of course, the amount of water obtained increases with increased air humidity. For example, in 100% relative humidity, about 200 mL/h of water can be collected. In general, the research results showed that thermoelectric coolers could be used to extract water from humid air, even in low humidity, with relatively good efficiency.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2024-12-01
DOI
https://doi.org/10.30492/ijcce.2024.2029165.6609
Primary Topic
Advanced Thermoelectric Materials and Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Experimental Study of the Application of Cooling Water in Taking Heat from a Thermoelectric Cooler Used in Extracting Water from Humid Air

SHILAP Revista de lepidopterología
Advanced Thermoelectric Materials and Devices
article

An Experimental Study of the Application of Cooling Water in Taking Heat from a Thermoelectric Cooler Used in Extracting Water from Humid Air

article en

Abstract

Humid air is one of the rich sources of water, especially in desert areas. One of the ways to extract water from humid air is to cool it down to a dew point in order to condense and collect water. This research applied a thermoelectric cooler for harvesting water from humid air. Cooling water was used to reject heat from the hot side of the thermoelectric. The effect of some parameters, such as the temperature, velocity, and humidity of the inlet air as well as the cooling water temperature, was investigated experimentally. The results showed that increasing the inlet air humidity and temperature increases the water collected. At a relative humidity of 20% and an air temperature of 35 oC, the maximum amount of water at an inlet air velocity of 1 m/s was equal to about 43 mL. Of course, the amount of water obtained increases with increased air humidity. For example, in 100% relative humidity, about 200 mL/h of water can be collected. In general, the research results showed that thermoelectric coolers could be used to extract water from humid air, even in low humidity, with relatively good efficiency.

SHILAP Revista de lepidopterología
Islamic Azad University of Shahreza (IR)
Clean water and sanitation
Openalex Percentile: Top 66%
Advanced Thermoelectric Materials and Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.