Analysis of the effect of using a variable speed drive on the power consumption of the ID fan drive motor

Cirebon Coal-Fired Power Plant Unit 1 uses an Induced Draft Fan (ID Fan) to regulate flue gas flow and maintain negative pressure inside the boiler. The current ID Fan control system still applies a blade pitch position mechanism with constant motor speed, resulting in high power consumption ranging from 2,547.9 kW to 4,311.2 kW. This condition is inefficient because the motor runs at constant speed regardless of changing load demands. This study aims to design a Variable Speed Drive (VSD) to control the ID Fan motor speed and analyze its impact on power consumption. The research was conducted using simulation with MATLAB/Simulink R2021a software. The VSD design consists of three main components: a three-phase rectifier, a buck converter-based DC link, and a three-phase PWM inverter, adjusted to meet the ID Fan operational pressure limit of 8.0 to 10.0 kPa. The simulation results show that with the implementation of VSD, the system pressure can be maintained within the safe range of 8.5 to 9.7 kPa, and the motor speed can be adjusted according to airflow demand. Power consumption decreased from 2,645.7 kW to 1,273.1 kW after implementing VSD, resulting in an energy saving of 62.1%. The application of VSD is proven to be effective in improving energy efficiency in the ID Fan system at the Cirebon Coal-Fired Power Plant Unit.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-11-20
DOI
https://doi.org/10.1051/e3sconf/202566402005/pdf
Primary Topic
Photovoltaic System Optimization Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of the effect of using a variable speed drive on the power consumption of the ID fan drive motor

Springer Link (Chiba Institute of Technology)
Photovoltaic System Optimization Techniques
article

Analysis of the effect of using a variable speed drive on the power consumption of the ID fan drive motor

article en

Abstract

Cirebon Coal-Fired Power Plant Unit 1 uses an Induced Draft Fan (ID Fan) to regulate flue gas flow and maintain negative pressure inside the boiler. The current ID Fan control system still applies a blade pitch position mechanism with constant motor speed, resulting in high power consumption ranging from 2,547.9 kW to 4,311.2 kW. This condition is inefficient because the motor runs at constant speed regardless of changing load demands. This study aims to design a Variable Speed Drive (VSD) to control the ID Fan motor speed and analyze its impact on power consumption. The research was conducted using simulation with MATLAB/Simulink R2021a software. The VSD design consists of three main components: a three-phase rectifier, a buck converter-based DC link, and a three-phase PWM inverter, adjusted to meet the ID Fan operational pressure limit of 8.0 to 10.0 kPa. The simulation results show that with the implementation of VSD, the system pressure can be maintained within the safe range of 8.5 to 9.7 kPa, and the motor speed can be adjusted according to airflow demand. Power consumption decreased from 2,645.7 kW to 1,273.1 kW after implementing VSD, resulting in an energy saving of 62.1%. The application of VSD is proven to be effective in improving energy efficiency in the ID Fan system at the Cirebon Coal-Fired Power Plant Unit.

Springer Link (Chiba Institute of Technology)
Affordable and clean energy
Openalex Percentile: Top 58%
Photovoltaic System Optimization Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.