Beam Rotation Capacity in Steel Dual Systems: Moment Frames and Eccentrically Braced Frames

Dual Systems are defined in ASCE 7-22 in section 12.2.5.1. They consist of a moment frame combined with a more rigid system, such as a shear wall or a braced frame, and are capable of supporting 25% of the design seismic load. When Dual Systems are combined with Excentric Braced Frames (EBF), they can allow a building to exceed the height limit of 160 ft, as specified in Table 12.2-1 of ASCE 7-22. In Costa Rica and other countries in Latin America, Dual Systems are commonly used to enhance the redundancy of the building. However, there is limited information available on the interaction between the two systems, particularly concerning connections. This research compares dual systems in fiveand nine-story buildings. A Push Over analysis was performed for both buildings, comparing their behavior with and without the moment frame. Inelastic beam rotations in the moment frame were evaluated at the life safety performance level. The results indicated that rotations were close to 0.02 radians at the lower stories. Overall, building strength improved with the use of dual systems in the taller structure.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-11-27
DOI
https://doi.org/10.1051/e3sconf/202566802002/pdf
Primary Topic
Seismic Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Beam Rotation Capacity in Steel Dual Systems: Moment Frames and Eccentrically Braced Frames

Springer Link (Chiba Institute of Technology)
Seismic Performance and Analysis
article

Beam Rotation Capacity in Steel Dual Systems: Moment Frames and Eccentrically Braced Frames

article en

Abstract

Dual Systems are defined in ASCE 7-22 in section 12.2.5.1. They consist of a moment frame combined with a more rigid system, such as a shear wall or a braced frame, and are capable of supporting 25% of the design seismic load. When Dual Systems are combined with Excentric Braced Frames (EBF), they can allow a building to exceed the height limit of 160 ft, as specified in Table 12.2-1 of ASCE 7-22. In Costa Rica and other countries in Latin America, Dual Systems are commonly used to enhance the redundancy of the building. However, there is limited information available on the interaction between the two systems, particularly concerning connections. This research compares dual systems in fiveand nine-story buildings. A Push Over analysis was performed for both buildings, comparing their behavior with and without the moment frame. Inelastic beam rotations in the moment frame were evaluated at the life safety performance level. The results indicated that rotations were close to 0.02 radians at the lower stories. Overall, building strength improved with the use of dual systems in the taller structure.

Springer Link (Chiba Institute of Technology)
Responsible consumption and production
Openalex Percentile: Top 46%
Seismic Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Beam Rotation Capacity in Steel Dual Systems: Moment Frames and Eccentrically Braced Frames · Springer Link (Chiba Institute of Technology) (2025) | TGRS Research Map | TGRS