Development of a Teleoperation System for a Continuum Robot Operated in a Leader–Follower Configuration

A man–machine teleoperation system for a continuum robot tailored to endovascular interventions and based on a leader–follower architecture is presented. The leader robotic catheter is manually shaped by the surgeon and equipped with distributed fiber-optic shape sensors. The follower catheter inserted into the patient’s vasculature is tracked exclusively by computer-vision algorithms and instrumented with force sensors. Inverse-kinematics algorithms reproduce the leader configuration on the follower, while a closed-loop sensory channel conveys contact forces to the operator as adjustable mechanical resistance, creating a tangible sense of presence. The system fulfils the core principles of collaborative robotics-intuitive manipulation, bidirectional feedback, adaptive motion constraints, and patient safety. Potential extensions include learning from demonstration and predictive control. The proposed system can serve as a foundation for next-generation robotic platforms enabling minimum invasive procedures under limited visual feedback.

Institutions

Publication Details

Journal
Journal of Communications Technology and Electronics
Published
2025-04-01
DOI
https://doi.org/10.1134/s1064226925700263
Primary Topic
Soft Robotics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a Teleoperation System for a Continuum Robot Operated in a Leader–Follower Configuration

Journal of Communications Technology and Electronics
Soft Robotics and Applications
article

Development of a Teleoperation System for a Continuum Robot Operated in a Leader–Follower Configuration

article en

Abstract

A man–machine teleoperation system for a continuum robot tailored to endovascular interventions and based on a leader–follower architecture is presented. The leader robotic catheter is manually shaped by the surgeon and equipped with distributed fiber-optic shape sensors. The follower catheter inserted into the patient’s vasculature is tracked exclusively by computer-vision algorithms and instrumented with force sensors. Inverse-kinematics algorithms reproduce the leader configuration on the follower, while a closed-loop sensory channel conveys contact forces to the operator as adjustable mechanical resistance, creating a tangible sense of presence. The system fulfils the core principles of collaborative robotics-intuitive manipulation, bidirectional feedback, adaptive motion constraints, and patient safety. Potential extensions include learning from demonstration and predictive control. The proposed system can serve as a foundation for next-generation robotic platforms enabling minimum invasive procedures under limited visual feedback.

Journal of Communications Technology and ElectronicsVol. 70(4)
V. A. Trapeznikov Institute of Control Sciences (RU)
Openalex Percentile: Top 47%
Soft Robotics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.