Study and simulation of small signal stability of gas turbine plant with combined LFC and AVR control loops in single area power system

In order to manage voltage and frequency stability, a hybrid model of two control loops including load frequency control and automatic voltage regulation is used in power systems. This paper focuses on a hybrid model that integrates load frequency control (LFC) and automatic voltage regulator (AVR) to ensure voltage and frequency stability in a single-area power system with a gas turbine power plant. The effect of these two control loops in a single-zone power system is investigated and simulated. The single-zone power system includes a gas turbine power plant, and a small-signal model is used to analyze the dynamic behavior of the power system. The system equations are represented in the state space model, and the simulation results are analyzed by calculating the system states. Also, to check the accuracy of the simulation results, the power system model is implemented in the MATLAB Simulink environment, which shows the accuracy of the simulation results and their analysis.

Institutions

Publication Details

Published
2025-07-19
DOI
https://doi.org/10.71939/jsme.2025.1212376
Primary Topic
Frequency Control in Power Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study and simulation of small signal stability of gas turbine plant with combined LFC and AVR control loops in single area power system

Frequency Control in Power Systems
article

Study and simulation of small signal stability of gas turbine plant with combined LFC and AVR control loops in single area power system

article en

Abstract

In order to manage voltage and frequency stability, a hybrid model of two control loops including load frequency control and automatic voltage regulation is used in power systems. This paper focuses on a hybrid model that integrates load frequency control (LFC) and automatic voltage regulator (AVR) to ensure voltage and frequency stability in a single-area power system with a gas turbine power plant. The effect of these two control loops in a single-zone power system is investigated and simulated. The single-zone power system includes a gas turbine power plant, and a small-signal model is used to analyze the dynamic behavior of the power system. The system equations are represented in the state space model, and the simulation results are analyzed by calculating the system states. Also, to check the accuracy of the simulation results, the power system model is implemented in the MATLAB Simulink environment, which shows the accuracy of the simulation results and their analysis.

Islamic Azad University of Najafabad (IR)
Affordable and clean energy
Openalex Percentile: Top 46%
Frequency Control in Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Study and simulation of small signal stability of gas turbine plant with combined LFC and AVR control loops in single area power system · (2025) | TGRS Research Map | TGRS