Detector Noise in X-ray Computed Tomography Examinations of Irradiated Tristructural Isotropic (TRISO) Fuels

Tristructural isotopic (TRISO) fuel is a promising next-generation fuel form for advanced nuclear reactors. TRISO fuel consists of sub-millimeter diameter uranium-bearing fuel kernels encapsulated in multiple layers of carbon and ceramic materials. As part of the assessment of TRISO fuels, post irradiation examination (PIE) is performed to provide information on changes in microstructure, mechanical properties, and potential degradation. X-ray computed tomography (XCT) is a nondestructive technique that collects a series of two-dimensional radiographs as a function of sample rotation and mathematically reconstructs them into a three-dimensional dataset that provides volumetric information on the sample’s internal features. This work focuses on PIE of irradiated TRISO fuels using XCT with a focus on examining the impact of highly radioactive fuels on the images generated with the instrument’s CsI detector. Despite examining samples with over 2.00 Sv/hr on contact, techniques such as frame-averaging as well as a lack of interaction of high-energy gamma-rays with the detector ensure there is no noticeable impact on the quality of the CT images due to detector noise.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-11-06
DOI
https://doi.org/10.1051/epjconf/202533805004/pdf
Primary Topic
Nuclear reactor physics and engineering
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detector Noise in X-ray Computed Tomography Examinations of Irradiated Tristructural Isotropic (TRISO) Fuels

Springer Link (Chiba Institute of Technology)
Nuclear reactor physics and engineering
article

Detector Noise in X-ray Computed Tomography Examinations of Irradiated Tristructural Isotropic (TRISO) Fuels

article en

Abstract

Tristructural isotopic (TRISO) fuel is a promising next-generation fuel form for advanced nuclear reactors. TRISO fuel consists of sub-millimeter diameter uranium-bearing fuel kernels encapsulated in multiple layers of carbon and ceramic materials. As part of the assessment of TRISO fuels, post irradiation examination (PIE) is performed to provide information on changes in microstructure, mechanical properties, and potential degradation. X-ray computed tomography (XCT) is a nondestructive technique that collects a series of two-dimensional radiographs as a function of sample rotation and mathematically reconstructs them into a three-dimensional dataset that provides volumetric information on the sample’s internal features. This work focuses on PIE of irradiated TRISO fuels using XCT with a focus on examining the impact of highly radioactive fuels on the images generated with the instrument’s CsI detector. Despite examining samples with over 2.00 Sv/hr on contact, techniques such as frame-averaging as well as a lack of interaction of high-energy gamma-rays with the detector ensure there is no noticeable impact on the quality of the CT images due to detector noise.

Springer Link (Chiba Institute of Technology)
Affordable and clean energy
Openalex Percentile: Top 28%
Nuclear reactor physics and engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Detector Noise in X-ray Computed Tomography Examinations of Irradiated Tristructural Isotropic (TRISO) Fuels · Springer Link (Chiba Institute of Technology) (2025) | TGRS Research Map | TGRS