The effect of surgical field suction flow rate and venous reservoir levels on gaseous microemboli transmission

Background: Minimizing Gaseous microemboli (GME) introduced into the CPB circuit can help alleviate neurologic injury. This study focuses on understanding how suction flow rate and the reservoir level can influence the introduction of GME past the venous reservoir during CPB. Methods: An in vitro mock CPB loop filled with bovine blood was used to simulate adult CPB. A Gampt BCC-300 bubble detector measured bubble size, volume, and count at three locations: post-reservoir (venous), post-oxygenator/arterial filter (arterial), and the venous inlet to the reservoir (recirculation). Room air was added into the suction line at 200 mL/min and mixed with blood to simulate aerated suction return. Bubble transmission was measured for three minutes at three reservoir levels, 200 mL, 500 mL, and 1000 mL, and at four pump sucker flow rates: 25 RPM (0.32 L/min), 50 RPM (0.65 L/min), 75 RPM (0.99 L/min), and 100 RPM (1.32 L/min). GME count data were pooled from three commonly used, coated, disposable reservoirs/oxygenator combinations: Medtronic Affinity Fusion, Terumo CAPIOX FX25, and Sorin Inspire 8F. Results: A total of 284 measurements were conducted, and the data from all reservoir manufacturers were analyzed and averaged. A statistically significant interaction was noticed between roller pump suction rate and reservoir level (p-value < 0.0001) at the venous sensor. As the suction flow rate increased, the reservoir level decreased, or a combination of the two occurred, a significant increase in GME count was observed at the post-reservoir sensor. Analysis of the GME count from the post-oxygenator/filter sensor revealed a significant increase as the suction flow rate increased from 25 RPM to 100 RPM. Conclusion: A minimum effective suction flow rate and maximum practical reservoir level are recommended to prevent the transmission of GME through the cardiopulmonary bypass circuit and potentially to the patient. Care should be taken to continuously monitor these variables throughout the case and adjust them accordingly.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2026-03-13
DOI
https://doi.org/10.1051/ject/2025067/pdf
Primary Topic
Cardiac and Coronary Surgery Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The effect of surgical field suction flow rate and venous reservoir levels on gaseous microemboli transmission

Springer Link (Chiba Institute of Technology)
Cardiac and Coronary Surgery Techniques
article

The effect of surgical field suction flow rate and venous reservoir levels on gaseous microemboli transmission

article en

Abstract

Background: Minimizing Gaseous microemboli (GME) introduced into the CPB circuit can help alleviate neurologic injury. This study focuses on understanding how suction flow rate and the reservoir level can influence the introduction of GME past the venous reservoir during CPB. Methods: An in vitro mock CPB loop filled with bovine blood was used to simulate adult CPB. A Gampt BCC-300 bubble detector measured bubble size, volume, and count at three locations: post-reservoir (venous), post-oxygenator/arterial filter (arterial), and the venous inlet to the reservoir (recirculation). Room air was added into the suction line at 200 mL/min and mixed with blood to simulate aerated suction return. Bubble transmission was measured for three minutes at three reservoir levels, 200 mL, 500 mL, and 1000 mL, and at four pump sucker flow rates: 25 RPM (0.32 L/min), 50 RPM (0.65 L/min), 75 RPM (0.99 L/min), and 100 RPM (1.32 L/min). GME count data were pooled from three commonly used, coated, disposable reservoirs/oxygenator combinations: Medtronic Affinity Fusion, Terumo CAPIOX FX25, and Sorin Inspire 8F. Results: A total of 284 measurements were conducted, and the data from all reservoir manufacturers were analyzed and averaged. A statistically significant interaction was noticed between roller pump suction rate and reservoir level (p-value < 0.0001) at the venous sensor. As the suction flow rate increased, the reservoir level decreased, or a combination of the two occurred, a significant increase in GME count was observed at the post-reservoir sensor. Analysis of the GME count from the post-oxygenator/filter sensor revealed a significant increase as the suction flow rate increased from 25 RPM to 100 RPM. Conclusion: A minimum effective suction flow rate and maximum practical reservoir level are recommended to prevent the transmission of GME through the cardiopulmonary bypass circuit and potentially to the patient. Care should be taken to continuously monitor these variables throughout the case and adjust them accordingly.

Springer Link (Chiba Institute of Technology)
Midwestern University
Openalex Percentile: Top 100%
Cardiac and Coronary Surgery Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The effect of surgical field suction flow rate and venous reservoir levels on gaseous microemboli transmission · Springer Link (Chiba Institute of Technology) (2026) | TGRS Research Map | TGRS