A Study on the Application of Heat Pump Systems Using Discharged Groundwater for Building Heating and Cooling

This study examines the performance and economic viability of a heat pump system that utilizes discharged groundwater for heating and cooling buildings. For comparison, systems using air and river water as heat sources were also analyzed. Thermal load predictions and energy consumption assessments for an office building were performed using the TRNSYS18 simulation program. The findings revealed that the discharged groundwater system achieved the highest seasonal performance factor (SPF), with values of 2.28 for heating and 3.21 for cooling. An economic evaluation was conducted using the air-source heat pump system as a baseline, focusing on both initial investment and operating costs. The results indicated that the groundwater and river-source systems could reduce annual operating costs by 24.1% and 19.0%, respectively, compared to the air-source system. Despite the higher SPF, the estimated payback periods were approximately 9 years for the groundwater system and 12 years for the river system.

Publication Details

Journal
Korean Journal of Air-Conditioning and Refrigeration Engineering
Published
2025-12-09
DOI
https://doi.org/10.6110/kjacr.2025.37.12.571
Primary Topic
Geothermal Energy Systems and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Study on the Application of Heat Pump Systems Using Discharged Groundwater for Building Heating and Cooling

Korean Journal of Air-Conditioning and Refrigeration Engineering
Geothermal Energy Systems and Applications
article

A Study on the Application of Heat Pump Systems Using Discharged Groundwater for Building Heating and Cooling

article en

Abstract

This study examines the performance and economic viability of a heat pump system that utilizes discharged groundwater for heating and cooling buildings. For comparison, systems using air and river water as heat sources were also analyzed. Thermal load predictions and energy consumption assessments for an office building were performed using the TRNSYS18 simulation program. The findings revealed that the discharged groundwater system achieved the highest seasonal performance factor (SPF), with values of 2.28 for heating and 3.21 for cooling. An economic evaluation was conducted using the air-source heat pump system as a baseline, focusing on both initial investment and operating costs. The results indicated that the groundwater and river-source systems could reduce annual operating costs by 24.1% and 19.0%, respectively, compared to the air-source system. Despite the higher SPF, the estimated payback periods were approximately 9 years for the groundwater system and 12 years for the river system.

Korean Journal of Air-Conditioning and Refrigeration EngineeringVol. 37(12)
Affordable and clean energy
Openalex Percentile: Top 60%
Geothermal Energy Systems and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Study on the Application of Heat Pump Systems Using Discharged Groundwater for Building Heating and Cooling · Korean Journal of Air-Conditioning and Refrigeration Engineering (2025) | TGRS Research Map | TGRS