Experimental analysis of Schottky-barrier 4H-SiC-detector-response to fast neutrons: Comparison with Si and diamond detectors

The response of 4H-SiC detectors to 17 MeV neutrons was experimentally analysed using detectors composed solely of carbon or silicon. The detectors were tested using three different neutron energies (14.5 MeV, 15 MeV and 17 MeV) at two different facilities with T(d,n) neutron generators, the Van de Graaff laboratory at IEAP CTU in Prague and at the DANAIDES facility at CEA research center in Cadarache. The calibration via interactions on 28Si nuclei, the (n, α) nuclear reaction to ground and excited states of 25Mg, was made. The standard deviation of experimental values measured by Si detector from prepared calibration curve, was of 0.073 MeV, which represents the uncertainty of less than 1% in this energy range (≈ 10 MeV). The experiment showed that the pulse height defect affects the measured spectra the way that the peak energies from the C interactions are shifted by about 0.5 MeV to higher values when the calibration from the Si interactions is used.

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2025-11-06
DOI
https://doi.org/10.1051/epjconf/202533810016/pdf
Primary Topic
Silicon Carbide Semiconductor Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental analysis of Schottky-barrier 4H-SiC-detector-response to fast neutrons: Comparison with Si and diamond detectors

Springer Link (Chiba Institute of Technology)
Silicon Carbide Semiconductor Technologies
article

Experimental analysis of Schottky-barrier 4H-SiC-detector-response to fast neutrons: Comparison with Si and diamond detectors

article en

Abstract

The response of 4H-SiC detectors to 17 MeV neutrons was experimentally analysed using detectors composed solely of carbon or silicon. The detectors were tested using three different neutron energies (14.5 MeV, 15 MeV and 17 MeV) at two different facilities with T(d,n) neutron generators, the Van de Graaff laboratory at IEAP CTU in Prague and at the DANAIDES facility at CEA research center in Cadarache. The calibration via interactions on 28Si nuclei, the (n, α) nuclear reaction to ground and excited states of 25Mg, was made. The standard deviation of experimental values measured by Si detector from prepared calibration curve, was of 0.073 MeV, which represents the uncertainty of less than 1% in this energy range (≈ 10 MeV). The experiment showed that the pulse height defect affects the measured spectra the way that the peak energies from the C interactions are shifted by about 0.5 MeV to higher values when the calibration from the Si interactions is used.

Springer Link (Chiba Institute of Technology)
Affordable and clean energy
Openalex Percentile: Top 47%
Silicon Carbide Semiconductor Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.