Monte Carlo embryo absorbed dose in caregivers assisting pediatric patients undergoing 18F-FDG PET torso examination

Abstract This study estimates the mean absorbed dose to the embryo of a pregnant caregiver assisting a child during an 18 F-FDG PET torso examination. Using the FLUKA Monte Carlo (MC) simulations, various clinical scenarios were modeled taking into account different ages of pediatric patients, caregiver’s positions and exposure scenarios. The accuracy and reliability of the simulation framework were validated by comparing its results with ICRP (Ann ICRP 38:7–96, 2008) and AAPM (Madsen et al. in Med Phys 33:4–15. 2006. https://doi.org/10.1118/1.2135911 ) data. Embryo dose estimates obtained using the FLUKA Monte Carlo code were also compared with those derived from ICRP Publication 116 (Ann ICRP 40(2–5):1–257, 2010). The embryo dose values obtained through the Monte Carlo simulations were consistently lower than the ICRP 116 values. Furthermore, these simulated doses were below the 1 mSv limit for the embryo/fetus over the entire pregnancy period (European Union in Off J Eur Union L 13:1–73, 2014) and the 3 mSv dose constraint for caregivers under 60 years old, as stipulated by Italian law (ITALIA in Gazz Uff Repub Ital Ser Gen, n. 201, 10 Aug. 2020, Suppl. ord. n. 29).

Institutions

Publication Details

Journal
The European Physical Journal Plus
Published
2025-12-07
DOI
https://doi.org/10.1140/epjp/s13360-025-07087-1
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Monte Carlo embryo absorbed dose in caregivers assisting pediatric patients undergoing 18F-FDG PET torso examination

The European Physical Journal Plus
Radiation Dose and Imaging
article

Monte Carlo embryo absorbed dose in caregivers assisting pediatric patients undergoing 18F-FDG PET torso examination

article en

Abstract

Abstract This study estimates the mean absorbed dose to the embryo of a pregnant caregiver assisting a child during an 18 F-FDG PET torso examination. Using the FLUKA Monte Carlo (MC) simulations, various clinical scenarios were modeled taking into account different ages of pediatric patients, caregiver’s positions and exposure scenarios. The accuracy and reliability of the simulation framework were validated by comparing its results with ICRP (Ann ICRP 38:7–96, 2008) and AAPM (Madsen et al. in Med Phys 33:4–15. 2006. https://doi.org/10.1118/1.2135911 ) data. Embryo dose estimates obtained using the FLUKA Monte Carlo code were also compared with those derived from ICRP Publication 116 (Ann ICRP 40(2–5):1–257, 2010). The embryo dose values obtained through the Monte Carlo simulations were consistently lower than the ICRP 116 values. Furthermore, these simulated doses were below the 1 mSv limit for the embryo/fetus over the entire pregnancy period (European Union in Off J Eur Union L 13:1–73, 2014) and the 3 mSv dose constraint for caregivers under 60 years old, as stipulated by Italian law (ITALIA in Gazz Uff Repub Ital Ser Gen, n. 201, 10 Aug. 2020, Suppl. ord. n. 29).

The European Physical Journal PlusVol. 140(12)
University of Rome Tor Vergata (IT), Bambino Gesù Children's Hospital (IT), Istituti di Ricovero e Cura a Carattere Scientifico (IT)
Ministero della Salute
Good health and well-being
Openalex Percentile: Top 34%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.