Design and performance of a novel data acquisition and processing system for the APS Upgrade front end XBPM

The APS-Upgrade (APS-U) ID beamline front ends are equipped with next-generation X-ray beam position monitors (XBPMs). Each XBPM utilizes 16-element array detectors to simultaneously capture beam distribution information from undulator and bend magnet (BM) sources. A novel IOC has been designed to handle the following tasks in real time: estimating and subtracting BM signals, applying undulator-gap-dependent calibration to calculate undulator beam center positions, collecting beam position statistics, and estimating X-ray RMS motion and XBPM resolution. Initial data from early APS-U user runs demonstrate significant performance improvements. The BM signal contribution is reduced by more than a factor of 10, observed RMS beam motion is within the micrometer range, and XBPM resolution is consistently below 1 micrometer, typically less than 10% of the RMS beam motion.

Publication Details

Journal
JACOW
Published
2025-12-05
DOI
https://doi.org/10.18429/jacow-icalepcs2025-tupd007
Primary Topic
Particle Accelerators and Free-Electron Lasers
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and performance of a novel data acquisition and processing system for the APS Upgrade front end XBPM

JACOW
Particle Accelerators and Free-Electron Lasers
article

Design and performance of a novel data acquisition and processing system for the APS Upgrade front end XBPM

article en

Abstract

The APS-Upgrade (APS-U) ID beamline front ends are equipped with next-generation X-ray beam position monitors (XBPMs). Each XBPM utilizes 16-element array detectors to simultaneously capture beam distribution information from undulator and bend magnet (BM) sources. A novel IOC has been designed to handle the following tasks in real time: estimating and subtracting BM signals, applying undulator-gap-dependent calibration to calculate undulator beam center positions, collecting beam position statistics, and estimating X-ray RMS motion and XBPM resolution. Initial data from early APS-U user runs demonstrate significant performance improvements. The BM signal contribution is reduced by more than a factor of 10, observed RMS beam motion is within the micrometer range, and XBPM resolution is consistently below 1 micrometer, typically less than 10% of the RMS beam motion.

JACOW
Openalex Percentile: Top 47%
Particle Accelerators and Free-Electron Lasers
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.