Isotopic measurements of Sr, Nd, Li and Mg standards using the Thermo ScientificTM TritonTM Plus mass spectrometer at the INGV - Osservatorio Vesuviano

At the Istituto Nazionale di Geofisica e Vulcanologia Osservatorio Vesuviano (INGVOV), highprecision Sr and Nd isotope ratios determinations have been carried out on geological and archaeological samples since 2002, by using a multicollector ThermoFinnigan™ mass spectrometer. In 2020 Li isotopes were measured in dynamic mode, following the chemical separation of this element from the matrix. In 2021, a task force was established in order to buy the Thermo Scientific™ Triton™ Plus Series Multicollector Thermal Ionization Mass Spectrometer and all the equipment required for its operation. It integrates the established fieldproven technologies from the Triton Series instruments with the latest developments in technology for isotope ratio analysis. The instrument enables highprecision isotopic measurements via thermal ionization and has an increased speed, sensitivity, and precision with the use of the 1013 Ω Amplifier Technology™. During the last years, following the installation of the Thermo Scientific™ Triton™ Plus mass spectrometer, the analyses of international reference standards of Sr, Nd, Li, and Mg have been performed in static mode, to configure the instrument and to verify the reproducibility of the measurements over time. The results demonstrate good reproducibility for all the standards. The mass spectrometer has also been configured for U isotopes measurements in dynamic mode using the secondary electron multiplier (SEM) detector, and isotopic analyses on the international reference standard are underway. Here we summarize the main features of the Thermo Scientific™ Triton™ Plus mass spectrometer, the procedures for Sr, Nd, Li, Mg isotopes determination and for the chemical separation of Mg by chromatographic technique on column (in addition to the already established separation schemes of Sr, Nd, Li). The combined use of all the mentioned systematics, in environmental and volcanological studies, represents the starting point for future challenges in the research activities of the Osservatorio Vesuviano.

Institutions

Publication Details

Journal
Istituto Nazionale di Geofisica e Vulcanologia (INGV)
Published
2025-09-23
DOI
https://doi.org/10.13127/rpt/506
Primary Topic
Geochemistry and Elemental Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Isotopic measurements of Sr, Nd, Li and Mg standards using the Thermo ScientificTM TritonTM Plus mass spectrometer at the INGV - Osservatorio Vesuviano

Istituto Nazionale di Geofisica e Vulcanologia (INGV)
Geochemistry and Elemental Analysis
article

Isotopic measurements of Sr, Nd, Li and Mg standards using the Thermo ScientificTM TritonTM Plus mass spectrometer at the INGV - Osservatorio Vesuviano

article en

Abstract

At the Istituto Nazionale di Geofisica e Vulcanologia Osservatorio Vesuviano (INGVOV), highprecision Sr and Nd isotope ratios determinations have been carried out on geological and archaeological samples since 2002, by using a multicollector ThermoFinnigan™ mass spectrometer. In 2020 Li isotopes were measured in dynamic mode, following the chemical separation of this element from the matrix. In 2021, a task force was established in order to buy the Thermo Scientific™ Triton™ Plus Series Multicollector Thermal Ionization Mass Spectrometer and all the equipment required for its operation. It integrates the established fieldproven technologies from the Triton Series instruments with the latest developments in technology for isotope ratio analysis. The instrument enables highprecision isotopic measurements via thermal ionization and has an increased speed, sensitivity, and precision with the use of the 1013 Ω Amplifier Technology™. During the last years, following the installation of the Thermo Scientific™ Triton™ Plus mass spectrometer, the analyses of international reference standards of Sr, Nd, Li, and Mg have been performed in static mode, to configure the instrument and to verify the reproducibility of the measurements over time. The results demonstrate good reproducibility for all the standards. The mass spectrometer has also been configured for U isotopes measurements in dynamic mode using the secondary electron multiplier (SEM) detector, and isotopic analyses on the international reference standard are underway. Here we summarize the main features of the Thermo Scientific™ Triton™ Plus mass spectrometer, the procedures for Sr, Nd, Li, Mg isotopes determination and for the chemical separation of Mg by chromatographic technique on column (in addition to the already established separation schemes of Sr, Nd, Li). The combined use of all the mentioned systematics, in environmental and volcanological studies, represents the starting point for future challenges in the research activities of the Osservatorio Vesuviano.

Istituto Nazionale di Geofisica e Vulcanologia (INGV)
Istituto Nazionale di Geofisica e Vulcanologia (IT)
Openalex Percentile: Top 37%
Geochemistry and Elemental Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Isotopic measurements of Sr, Nd, Li and Mg standards using the Thermo ScientificTM TritonTM Plus mass spectrometer at the INGV - Osservatorio Vesuviano · Istituto Nazionale di Geofisica e Vulcanologia (INGV) (2025) | TGRS Research Map | TGRS