A digital twin-enhanced decision support system improves time-in-range in type 1 diabetes: a randomized clinical trial.

Most individuals with type 1 diabetes (T1D) worldwide continue to be managed with multiple daily injections or sensor-augmented pumps. Decision-support systems (DSSs) have emerged as cost-effective tools to enhance treatment adherence and glucose control. We conducted a randomized, open-label, parallel-group study to evaluate STUDIA, a DSS incorporating a digital twin-enabled simulation-assisted bolus calculator. Twenty-eight participants with T1D used either the simulation-assisted calculator or traditional carbohydrate counting for prandial insulin dosing, with glucose monitored using Freestyle Libre. After four weeks, the group using the simulation-assisted calculator showed a 7% increase in time in the target glucose range (70-180 mg/dL) compared to the control (p < 0.001), along with a lower hypoglycemia incidence rate (RR 0.31, p = 0.022). Model performance yielded a mean absolute percentage error at 60 min of 19.2 ± 6.7%, increasing at longer horizons, with most discrepancies between simulation and sensor falling into no-risk or slight-risk zones. These findings support the safety, feasibility, and potential clinical utility of the STUDIA system in people with T1D.

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-11-13
DOI
https://doi.org/10.48620/92783
Primary Topic
Diabetes Management and Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A digital twin-enhanced decision support system improves time-in-range in type 1 diabetes: a randomized clinical trial.

Open Access CRIS of the University of Bern
Diabetes Management and Research
article

A digital twin-enhanced decision support system improves time-in-range in type 1 diabetes: a randomized clinical trial.

article en

Abstract

Most individuals with type 1 diabetes (T1D) worldwide continue to be managed with multiple daily injections or sensor-augmented pumps. Decision-support systems (DSSs) have emerged as cost-effective tools to enhance treatment adherence and glucose control. We conducted a randomized, open-label, parallel-group study to evaluate STUDIA, a DSS incorporating a digital twin-enabled simulation-assisted bolus calculator. Twenty-eight participants with T1D used either the simulation-assisted calculator or traditional carbohydrate counting for prandial insulin dosing, with glucose monitored using Freestyle Libre. After four weeks, the group using the simulation-assisted calculator showed a 7% increase in time in the target glucose range (70-180 mg/dL) compared to the control (p < 0.001), along with a lower hypoglycemia incidence rate (RR 0.31, p = 0.022). Model performance yielded a mean absolute percentage error at 60 min of 19.2 ± 6.7%, increasing at longer horizons, with most discrepancies between simulation and sensor falling into no-risk or slight-risk zones. These findings support the safety, feasibility, and potential clinical utility of the STUDIA system in people with T1D.

Open Access CRIS of the University of Bern
Diabetes Australia (AU)
Openalex Percentile: Top 35%
Diabetes Management and Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.