Quantifying the consequence of anterior-surface polishing time on the optical performance of wavefront-guided scleral lenses

The process for manufacturing wavefront-guided scleral lenses includes polishing both the anterior and posterior lens surfaces. The purpose of this study was to determine if extended front-surface polishing durations induce aberration changes in wavefront-guided scleral lenses that exceed manufacturing tolerances. Two sets of six scleral lenses were manufactured. Each set contained one reference lens with only sphere correction and five wavefront-guided scleral lenses, all of which shared the same wavefront-correcting optics. After cutting, the anterior surfaces of the five wavefront-guided lenses in both sets were polished for differing durations. Set 1 lenses were polished with a used polishing cloth, and Set 2 were polished with a brand-new polishing cloth. Aberrations in each polished lens were measured with a wavefront sensor and examined as a function of polishing time. Changes in aberrations that would be clinically significant and/or greater than manufacturing tolerances were not observed for the material or polishing times studied or the remaining lifetime of the polishing cloth.

Publication Details

Journal
Journal of the Optical Society of America A
Published
2025-12-04
DOI
https://doi.org/10.1364/josaa.582536
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantifying the consequence of anterior-surface polishing time on the optical performance of wavefront-guided scleral lenses

Journal of the Optical Society of America A
Ophthalmology and Visual Impairment Studies
article

Quantifying the consequence of anterior-surface polishing time on the optical performance of wavefront-guided scleral lenses

article en

Abstract

The process for manufacturing wavefront-guided scleral lenses includes polishing both the anterior and posterior lens surfaces. The purpose of this study was to determine if extended front-surface polishing durations induce aberration changes in wavefront-guided scleral lenses that exceed manufacturing tolerances. Two sets of six scleral lenses were manufactured. Each set contained one reference lens with only sphere correction and five wavefront-guided scleral lenses, all of which shared the same wavefront-correcting optics. After cutting, the anterior surfaces of the five wavefront-guided lenses in both sets were polished for differing durations. Set 1 lenses were polished with a used polishing cloth, and Set 2 were polished with a brand-new polishing cloth. Aberrations in each polished lens were measured with a wavefront sensor and examined as a function of polishing time. Changes in aberrations that would be clinically significant and/or greater than manufacturing tolerances were not observed for the material or polishing times studied or the remaining lifetime of the polishing cloth.

Journal of the Optical Society of America AVol. 43(2)
Openalex Percentile: Top 34%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Quantifying the consequence of anterior-surface polishing time on the optical performance of wavefront-guided scleral lenses · Journal of the Optical Society of America A (2025) | TGRS Research Map | TGRS