Novel Use of a Soehendra Biliary Dilatation Catheter and Controlled Radial Expansion Balloon To Gain Access Through an Existing Duodenal Stent via Complex Endoscopic Retrograde Cholangiopancreatography: A Case Report

We report the case of a malignant type II duodenal stricture treated with an uncovered duodenal stent, later requiring endoscopic retrograde cholangiopancreatography (ERCP) for biliary obstruction. The ampulla was covered with a stent mesh. The procedure was performed through the meshed duodenal stent to access the bile duct. In our case, we used a Soehendra Biliary Dilatation Catheter (Cook Medical®, Limerick, Ireland) and controlled radial expansion (CRE) to facilitate the passage of a fully covered self-expandable metal stent through the mesh. This technique has not been previously described in the literature. It demonstrates the feasibility of accessing malignant strictures in palliated patients by the use of a CRE balloon and a Soehendra Biliary Dilatation Catheter to widen the uncovered duodenal stent mesh in complex ERCP cases.

Institutions

Publication Details

Journal
Cureus
Published
2025-12-03
DOI
https://doi.org/10.7759/cureus.98358
Primary Topic
Gallbladder and Bile Duct Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel Use of a Soehendra Biliary Dilatation Catheter and Controlled Radial Expansion Balloon To Gain Access Through an Existing Duodenal Stent via Complex Endoscopic Retrograde Cholangiopancreatography: A Case Report

Cureus
Gallbladder and Bile Duct Disorders
article

Novel Use of a Soehendra Biliary Dilatation Catheter and Controlled Radial Expansion Balloon To Gain Access Through an Existing Duodenal Stent via Complex Endoscopic Retrograde Cholangiopancreatography: A Case Report

article en

Abstract

We report the case of a malignant type II duodenal stricture treated with an uncovered duodenal stent, later requiring endoscopic retrograde cholangiopancreatography (ERCP) for biliary obstruction. The ampulla was covered with a stent mesh. The procedure was performed through the meshed duodenal stent to access the bile duct. In our case, we used a Soehendra Biliary Dilatation Catheter (Cook Medical®, Limerick, Ireland) and controlled radial expansion (CRE) to facilitate the passage of a fully covered self-expandable metal stent through the mesh. This technique has not been previously described in the literature. It demonstrates the feasibility of accessing malignant strictures in palliated patients by the use of a CRE balloon and a Soehendra Biliary Dilatation Catheter to widen the uncovered duodenal stent mesh in complex ERCP cases.

CureusVol. 17(12)
Wythenshawe Hospital (GB)
Openalex Percentile: Top 32%
Gallbladder and Bile Duct Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.