A Technical Framework Analysis of Digital Twin Control Algorithms for HVAC-BMS Integration and Implementation Challenges for Malaysian Green Buildings

Digital Twin technology offers transformative potential for integrating Heating, Ventilation, and Air Conditioning (HVAC) systems with Building Management Systems (BMS) in Malaysian green buildings. While proven effective in temperate regions, its application in tropical climates presents unique challenges, including high humidity, intense solar radiation, and consistently elevated temperatures. This paper examines current trends and prospects of Digital Twin applications in HVAC-BMS integration for Malaysian green buildings, focusing on implementation status, climate-specific adaptations, and potential benefits. Using PRISMA methodology, 36 articles published between 2020 - 2024 were systematically reviewed, analysing implementation frameworks, energy optimization strategies, and security considerations. Findings reveal that Model Predictive Control (MPC) algorithms achieve a 35.9% improvement in coefficient of performance compared to conventional Proportional-Integral-Derivative (PID) controllers, with energy consumption reductions of 23% - 30% across various building types. MPC-based Digital Twins demonstrate superior temperature control accuracy (± 0.4 C vs. ± 1.8 C) and humidity control precision (± 2.3 % RH vs. ± 7.5 % RH) compared to conventional systems. Implementation assessment reveals that GBI-certified buildings achieve significantly higher adoption rates (28%) compared to non-certified buildings (7%), with maturity levels primarily ranging from 1 to 3 on the 5-level framework. Break-even points typically occur between 2.2 - 3.1 years, with ROI averaging 120% - 150% over five years. Security implementation increased dramatically from 34% prior to 2022 to 87%after 2022, reflecting a heightened awareness of cybersecurity. The study concludes that Digital Twin technology offers substantial benefits for Malaysian green buildings when properly adapted to local conditions, with phased implementation approaches and public-private partnerships identified as key enablers for broader adoption supporting national sustainability objectives.

Publication Details

Journal
Journal of Mechanical Engineering
Published
2025-11-15
DOI
https://doi.org/10.24191/jmeche.v14i1.8753
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Technical Framework Analysis of Digital Twin Control Algorithms for HVAC-BMS Integration and Implementation Challenges for Malaysian Green Buildings

Journal of Mechanical Engineering
Building Energy and Comfort Optimization
article

A Technical Framework Analysis of Digital Twin Control Algorithms for HVAC-BMS Integration and Implementation Challenges for Malaysian Green Buildings

article en

Abstract

Digital Twin technology offers transformative potential for integrating Heating, Ventilation, and Air Conditioning (HVAC) systems with Building Management Systems (BMS) in Malaysian green buildings. While proven effective in temperate regions, its application in tropical climates presents unique challenges, including high humidity, intense solar radiation, and consistently elevated temperatures. This paper examines current trends and prospects of Digital Twin applications in HVAC-BMS integration for Malaysian green buildings, focusing on implementation status, climate-specific adaptations, and potential benefits. Using PRISMA methodology, 36 articles published between 2020 - 2024 were systematically reviewed, analysing implementation frameworks, energy optimization strategies, and security considerations. Findings reveal that Model Predictive Control (MPC) algorithms achieve a 35.9% improvement in coefficient of performance compared to conventional Proportional-Integral-Derivative (PID) controllers, with energy consumption reductions of 23% - 30% across various building types. MPC-based Digital Twins demonstrate superior temperature control accuracy (± 0.4 C vs. ± 1.8 C) and humidity control precision (± 2.3 % RH vs. ± 7.5 % RH) compared to conventional systems. Implementation assessment reveals that GBI-certified buildings achieve significantly higher adoption rates (28%) compared to non-certified buildings (7%), with maturity levels primarily ranging from 1 to 3 on the 5-level framework. Break-even points typically occur between 2.2 - 3.1 years, with ROI averaging 120% - 150% over five years. Security implementation increased dramatically from 34% prior to 2022 to 87%after 2022, reflecting a heightened awareness of cybersecurity. The study concludes that Digital Twin technology offers substantial benefits for Malaysian green buildings when properly adapted to local conditions, with phased implementation approaches and public-private partnerships identified as key enablers for broader adoption supporting national sustainability objectives.

Journal of Mechanical EngineeringVol. 14(SI 2025)
Universiti Tun Hussein Onn Malaysia
Openalex Percentile: Top 45%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.