Energy spectra from ionising radiation in the troposphere and stratosphere measured with a super-miniaturised scintillator detector

Motivated by the need to measure and understand the role of energetic particles in atmospheric processes, a super-miniaturised (40 g) CsI(Tl) scintillator (“microscintillator”) coupled to a PiN photodiode has been developed and tested in the atmosphere up to an altitude of 32 km. Specifically, a microscintillator and Geiger counters were flown with a meteorological radiosonde in July 2024. Separately, a hand-held microscintillator was carried on transatlantic passenger flights in March 2025. These deployments all occurred during calm space weather conditions, meaning that particles created by the galactic cosmic ray (GCR) background could be measured within the energy range of the instrument, 0.02–10 MeV. Geiger and microscintillator count rates from the balloon were well-correlated, with maximum count rates at ∼21 km, consistent with previous work. The spectral peak was centred on 1–2 MeV with an exponential decay coefficient of ∼0.5 MeV, consistent with the background GCR gamma spectrum. Energy spectra from the balloon and passenger flight at 10–12 km were consistent, with minor differences explained by lower-energy gammas and electrons not penetrating the plane's fuselage. Spectral lines from gammas created by GCR-neutron interactions with the atmosphere were detected in airborne data and were absent from ground-based data. These technology demonstrator flights provide background reference GCR ionising radiation spectra for comparison with more disturbed space weather conditions, where additional particles would be expected. Detection of gamma rays from GCR neutrons offers a way to directly calibrate neutrons measured at Earth's surface to ionising radiation in the atmosphere. • Novel 0.8 cm 3 CsI(Tl) scintillator-PiN diode flown on weather balloon up to 32 km. • Energy spectrum slope and lines indicative of galactic cosmic rays (GCR). • Results are self-consistent across multiple flights and with balloon-borne Geiger counters. • Reference GCR background spectra measured under calm space weather conditions. • GCR-related lines link ionising radiation to surface neutron monitor network.

Institutions

Publication Details

Journal
Radiation Measurements
Published
2025-12-03
DOI
https://doi.org/10.1016/j.radmeas.2025.107581
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Energy spectra from ionising radiation in the troposphere and stratosphere measured with a super-miniaturised scintillator detector

Radiation Measurements
Radiation Therapy and Dosimetry
article

Energy spectra from ionising radiation in the troposphere and stratosphere measured with a super-miniaturised scintillator detector

article en

Abstract

Motivated by the need to measure and understand the role of energetic particles in atmospheric processes, a super-miniaturised (40 g) CsI(Tl) scintillator (“microscintillator”) coupled to a PiN photodiode has been developed and tested in the atmosphere up to an altitude of 32 km. Specifically, a microscintillator and Geiger counters were flown with a meteorological radiosonde in July 2024. Separately, a hand-held microscintillator was carried on transatlantic passenger flights in March 2025. These deployments all occurred during calm space weather conditions, meaning that particles created by the galactic cosmic ray (GCR) background could be measured within the energy range of the instrument, 0.02–10 MeV. Geiger and microscintillator count rates from the balloon were well-correlated, with maximum count rates at ∼21 km, consistent with previous work. The spectral peak was centred on 1–2 MeV with an exponential decay coefficient of ∼0.5 MeV, consistent with the background GCR gamma spectrum. Energy spectra from the balloon and passenger flight at 10–12 km were consistent, with minor differences explained by lower-energy gammas and electrons not penetrating the plane's fuselage. Spectral lines from gammas created by GCR-neutron interactions with the atmosphere were detected in airborne data and were absent from ground-based data. These technology demonstrator flights provide background reference GCR ionising radiation spectra for comparison with more disturbed space weather conditions, where additional particles would be expected. Detection of gamma rays from GCR neutrons offers a way to directly calibrate neutrons measured at Earth's surface to ionising radiation in the atmosphere. • Novel 0.8 cm 3 CsI(Tl) scintillator-PiN diode flown on weather balloon up to 32 km. • Energy spectrum slope and lines indicative of galactic cosmic rays (GCR). • Results are self-consistent across multiple flights and with balloon-borne Geiger counters. • Reference GCR background spectra measured under calm space weather conditions. • GCR-related lines link ionising radiation to surface neutron monitor network.

Radiation MeasurementsVol. 191
Atkins (United States) (US), Paul Scherrer Institute (CH), University of Bristol (GB), Atkins (United Kingdom) (GB)
Affordable and clean energy
Openalex Percentile: Top 32%
Radiation Therapy and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.