Effect of air inlet velocity on air water harvester with small tube evaporator

During the dry season, parts of Indonesia experience drought and clean water crises. One of the efforts to obtain clean water was by presenting a machine called air-water harvester. The amount of water mass produced depended on several variables such as RH, intake air temperature, type of condensing unit, intake air velocity and engine power. This study aims to determine the performance of the air-water harvester at various inlet air velocities. The dependent variables expected were the mass of water produced, COP, and the amount of heat absorbed from the air. This research was carried out experimentally with the working fluid refrigerant R134a. The compressor used was a rotary type 1 PK compressor. This study varied the air velocity entering the evaporator, namely 1.5 m/s, 3 m/s and 4.5 m/s. The results showed that the highest mass of water was 0.728 kg. Meanwhile, the highest COP was 5.13, and the total heat transfer rate absorbed by the evaporator was 160.38 W. All were obtained at the air velocity of 4.5 m/s.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-06-30
DOI
https://doi.org/10.5281/zenodo.17774886
Primary Topic
Fluid dynamics and aerodynamics studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of air inlet velocity on air water harvester with small tube evaporator

Zenodo (CERN European Organization for Nuclear Research)
Fluid dynamics and aerodynamics studies
article

Effect of air inlet velocity on air water harvester with small tube evaporator

article en

Abstract

During the dry season, parts of Indonesia experience drought and clean water crises. One of the efforts to obtain clean water was by presenting a machine called air-water harvester. The amount of water mass produced depended on several variables such as RH, intake air temperature, type of condensing unit, intake air velocity and engine power. This study aims to determine the performance of the air-water harvester at various inlet air velocities. The dependent variables expected were the mass of water produced, COP, and the amount of heat absorbed from the air. This research was carried out experimentally with the working fluid refrigerant R134a. The compressor used was a rotary type 1 PK compressor. This study varied the air velocity entering the evaporator, namely 1.5 m/s, 3 m/s and 4.5 m/s. The results showed that the highest mass of water was 0.728 kg. Meanwhile, the highest COP was 5.13, and the total heat transfer rate absorbed by the evaporator was 160.38 W. All were obtained at the air velocity of 4.5 m/s.

Zenodo (CERN European Organization for Nuclear Research)
University of Mataram (ID)
Clean water and sanitation
Openalex Percentile: Top 40%
Fluid dynamics and aerodynamics studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.