Detection of Posterior Capsule Integrity in Posterior Polar Cataract during Pre-operative Biometry Using Swept Source OCT

Abstract Aim: To identify eyes with posterior polar cataract at a high risk of posterior capsule rupture (PCR) during pre-operative biometry by using swept-source optical coherence tomography (OCT) based IOL master 700. Settings: Tertiary care ophthalmic hospital. Design: Prospective, observational study. Methods and Material: Eyes clinically diagnosed with posterior polar cataracts (PPC) that have undergone biometry using the IOL master 700 followed by phacoemulsification were included. Posterior capsule (PC) integrity was categorized as intact or dehiscent using IOL master 700 OCT images taken during pre-operative biometry. Intraoperative status of the PC was noted and the sensitivity, specificity, negative predictive value and positive predictive value of IOL master 700 to detect pre-existing posterior capsular dehiscence was determined. Results: One hundred thirteen eyes of 105 patients were included. IOL master 700 OCT images showed intact PC in 105 eyes (88.3%) and PC dehiscence in 14 eyes (11.7%) pre-operatively. Out of the 105 eyes that were identified as intact PC, 101 eyes (96.2%) underwent uneventful surgery. Four eyes (3.8%) eyes had intra-operative PCR which had intact PC on imaging. PC dehiscence was identified in 14 eyes (11.7%) all of which had PCR intraoperatively (100%) which is statistically significant ( P < 0.001). IOL master 700 has a sensitivity of 77.8% and specificity of 100% in detecting eyes with PC dehiscence that are at high risk of PCR. The positive predictive value of detecting posterior capsule dehiscence was 100% and the negative predictive value was 96.2%. Conclusions: IOL master 700 can be effectively used to identify eyes at high risk of PCR during pre-operative biometry.

Institutions

Publication Details

Journal
TNOA Journal of Ophthalmic Science and Research
Published
2025-10-01
DOI
https://doi.org/10.4103/tjosr.tjosr_127_25
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detection of Posterior Capsule Integrity in Posterior Polar Cataract during Pre-operative Biometry Using Swept Source OCT

TNOA Journal of Ophthalmic Science and Research
Intraocular Surgery and Lenses
article

Detection of Posterior Capsule Integrity in Posterior Polar Cataract during Pre-operative Biometry Using Swept Source OCT

article en

Abstract

Abstract Aim: To identify eyes with posterior polar cataract at a high risk of posterior capsule rupture (PCR) during pre-operative biometry by using swept-source optical coherence tomography (OCT) based IOL master 700. Settings: Tertiary care ophthalmic hospital. Design: Prospective, observational study. Methods and Material: Eyes clinically diagnosed with posterior polar cataracts (PPC) that have undergone biometry using the IOL master 700 followed by phacoemulsification were included. Posterior capsule (PC) integrity was categorized as intact or dehiscent using IOL master 700 OCT images taken during pre-operative biometry. Intraoperative status of the PC was noted and the sensitivity, specificity, negative predictive value and positive predictive value of IOL master 700 to detect pre-existing posterior capsular dehiscence was determined. Results: One hundred thirteen eyes of 105 patients were included. IOL master 700 OCT images showed intact PC in 105 eyes (88.3%) and PC dehiscence in 14 eyes (11.7%) pre-operatively. Out of the 105 eyes that were identified as intact PC, 101 eyes (96.2%) underwent uneventful surgery. Four eyes (3.8%) eyes had intra-operative PCR which had intact PC on imaging. PC dehiscence was identified in 14 eyes (11.7%) all of which had PCR intraoperatively (100%) which is statistically significant ( P < 0.001). IOL master 700 has a sensitivity of 77.8% and specificity of 100% in detecting eyes with PC dehiscence that are at high risk of PCR. The positive predictive value of detecting posterior capsule dehiscence was 100% and the negative predictive value was 96.2%. Conclusions: IOL master 700 can be effectively used to identify eyes at high risk of PCR during pre-operative biometry.

TNOA Journal of Ophthalmic Science and ResearchVol. 63(4)
Aravind Eye Hospital (IN)
Openalex Percentile: Top 33%
Intraocular Surgery and Lenses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.