Analysis of Harmonic Improvement in the Computer Laboratory of Samarinda State Polytechnic with the Addition of a Static VAR Compensator

Abstract : An electrical system is said to have a high level of reliability if it is capable of supplying electrical energy continuously and in accordance with user needs. The quality of electrical power can be disrupted by the use of non-linear loads, such as computer devices, electronic devices, and energy-saving lamps. Harmonic problems in power quality arise due to the interaction between the sinusoidal waves of the system and the characteristics of non-linear loads, such as those found in the Computer Laboratory of the Samarinda State Polytechnic, which results in high harmonic current values. To determine the actual conditions, electrical parameters were measured. The results of the measurements showed a total current harmonic distortion value of 33.65% in phase R, 15.85% in phase S, and 92.99% in phase T. The individual current harmonic distortion in phase R decreased from 28.39% to 4.53%, to 3.76% in phase S, and to 2.63% in phase T on Thursday at 15:00 WITA. To overcome this, the use of a Static Var Compensator (SVC) is proposed as a solution to reduce the level of harmonics in the electrical system at the Computer Laboratory of the Samarinda State Polytechnic. The simulation was conducted using Matlab R2023a software through the Simulink feature. The results obtained show that the Static Var Compensator can reduce harmonics well, as seen from the harmonic values on Thursday, where before the Static Var Compensator was installed, the harmonics in phase R were 9.81%, phase S were 10.98%, and phase T were 9%.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-11-27
DOI
https://doi.org/10.5281/zenodo.17745852
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Harmonic Improvement in the Computer Laboratory of Samarinda State Polytechnic with the Addition of a Static VAR Compensator

Zenodo (CERN European Organization for Nuclear Research)
Power Quality and Harmonics
article

Analysis of Harmonic Improvement in the Computer Laboratory of Samarinda State Polytechnic with the Addition of a Static VAR Compensator

article en

Abstract

Abstract : An electrical system is said to have a high level of reliability if it is capable of supplying electrical energy continuously and in accordance with user needs. The quality of electrical power can be disrupted by the use of non-linear loads, such as computer devices, electronic devices, and energy-saving lamps. Harmonic problems in power quality arise due to the interaction between the sinusoidal waves of the system and the characteristics of non-linear loads, such as those found in the Computer Laboratory of the Samarinda State Polytechnic, which results in high harmonic current values. To determine the actual conditions, electrical parameters were measured. The results of the measurements showed a total current harmonic distortion value of 33.65% in phase R, 15.85% in phase S, and 92.99% in phase T. The individual current harmonic distortion in phase R decreased from 28.39% to 4.53%, to 3.76% in phase S, and to 2.63% in phase T on Thursday at 15:00 WITA. To overcome this, the use of a Static Var Compensator (SVC) is proposed as a solution to reduce the level of harmonics in the electrical system at the Computer Laboratory of the Samarinda State Polytechnic. The simulation was conducted using Matlab R2023a software through the Simulink feature. The results obtained show that the Static Var Compensator can reduce harmonics well, as seen from the harmonic values on Thursday, where before the Static Var Compensator was installed, the harmonics in phase R were 9.81%, phase S were 10.98%, and phase T were 9%.

Zenodo (CERN European Organization for Nuclear Research)
Universitas 17 Agustus 1945 Samarinda (ID)
Affordable and clean energy
Openalex Percentile: Top 47%
Power Quality and Harmonics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis of Harmonic Improvement in the Computer Laboratory of Samarinda State Polytechnic with the Addition of a Static VAR Compensator · Zenodo (CERN European Organization for Nuclear Research) (2025) | TGRS Research Map | TGRS