Numerical Simulation of the Impact of Smoke Management Scenarios on Visibility of a Car Park

The mechanical ventilation smoke management system involves the use of supply fans, jet fans, and exhaust fans, which are activated at different times after a fire is extinguished. This paper numerically investigates the effect of the priority and delay of smoke management systems on smoke distribution and visibility in a car park after a fire, using Fire Dynamic Simulation Code 6.7.6. The flow rates of the exhaust fan, supply fan, and jet fan are 1.9 m³/s, 1.43 m³/s, and 1.67 m³/s, respectively. The fire, located near the supply fans, is modeled as a rectangle with dimensions of 2.0 × 0.8 m² and a power of 1.6 MW, lasting for one minute from ignition to extinguishment. Polyurethane is assumed as a flammable material. The priority and delay of the smoke management systems are evaluated through four scenarios over a period of 420 seconds. The results show that visibility reaches acceptable levels in all scenarios at all locations after 420 seconds. Additionally, the results indicate that the visibility of the upper half is highest for scenario a, at around 15 m. However, the visibility of the lower half is highest for scenario d, ranging between 20 and 30 m. It can be concluded that delaying the activation of smoke management systems is an effective strategy for facilitating smoke removal and fresh air intake.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-04-01
DOI
https://doi.org/10.22060/ajme.2025.23512.6140
Primary Topic
Fire dynamics and safety research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical Simulation of the Impact of Smoke Management Scenarios on Visibility of a Car Park

SHILAP Revista de lepidopterología
Fire dynamics and safety research
article

Numerical Simulation of the Impact of Smoke Management Scenarios on Visibility of a Car Park

article en

Abstract

The mechanical ventilation smoke management system involves the use of supply fans, jet fans, and exhaust fans, which are activated at different times after a fire is extinguished. This paper numerically investigates the effect of the priority and delay of smoke management systems on smoke distribution and visibility in a car park after a fire, using Fire Dynamic Simulation Code 6.7.6. The flow rates of the exhaust fan, supply fan, and jet fan are 1.9 m³/s, 1.43 m³/s, and 1.67 m³/s, respectively. The fire, located near the supply fans, is modeled as a rectangle with dimensions of 2.0 × 0.8 m² and a power of 1.6 MW, lasting for one minute from ignition to extinguishment. Polyurethane is assumed as a flammable material. The priority and delay of the smoke management systems are evaluated through four scenarios over a period of 420 seconds. The results show that visibility reaches acceptable levels in all scenarios at all locations after 420 seconds. Additionally, the results indicate that the visibility of the upper half is highest for scenario a, at around 15 m. However, the visibility of the lower half is highest for scenario d, ranging between 20 and 30 m. It can be concluded that delaying the activation of smoke management systems is an effective strategy for facilitating smoke removal and fresh air intake.

SHILAP Revista de lepidopterología
Mashhad University of Medical Sciences (IR), University of Qom (IR)
Good health and well-being
Openalex Percentile: Top 41%
Fire dynamics and safety research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.