A morphometric lung model for evaluating lung aeration at birth

• We adapted a 3-D adult lung morphometric model to represent the preterm newborn lung. • We modeled changing airway mechanics during lung aeration at birth with lumped elements. • Combining morphometry and airway mechanical models, we simulated lung aeration at birth. • An integrated circuit simulator allowed for the solution of the entire network in the time domain. • This approach may contribute to defining lung protective resuscitation strategies at birth. Lung aeration must rapidly develop at birth, but how to promote it without injuring the fragile lung is still unknown. Mathematical models simulating lung mechanics during this transition may help understand the underlying physiological mechanisms and design protective ventilation strategies. This study develops a morphologically-coherent computational lung model incorporating changing physical conditions during the transition from liquid-filled to gas-filled lungs. We adapted a 3-D morphological model of the adult airway tree adjusting airway dimensions, lung volume, and lung tissue mechanical properties. Changes in resistance, inertia, and compliance during aeration were modeled by considering the differing properties of fetal fluid versus air. The capillary pressure at the liquid–air interface was computed using Laplace equation. Terminal airway diameters increased with lung volume due to airway-parenchymal interdependence. An integrated circuit simulator solved the entire network in the time domain. The air volume entering the model at different applied pressures increased exponentially with time. With 30 cmH 2 O applied, lung volume reached total capacity after 15 s, matching lung aeration dynamics observed in animal models and human infants. In contrast, after the same time, at 15 cmH 2 O, lung volume was slightly above functional residual capacity, and at 10 cmH 2 O, it remained below. The proposed in-silico newborn lung model simulates lung aeration at birth, allowing observation of the airway emptying sequence and the heterogeneity of aeration at each time point. Integrating this model with comprehensive acinar models may aid in defining protective resuscitation ventilation strategies for recruiting the lung minimizing risk of injuries.

Institutions

Publication Details

Journal
Journal of Applied Biomedicine
Published
2025-10-01
DOI
https://doi.org/10.1016/j.bbe.2025.11.004
Primary Topic
Neonatal Respiratory Health Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A morphometric lung model for evaluating lung aeration at birth

Journal of Applied Biomedicine
Neonatal Respiratory Health Research
article

A morphometric lung model for evaluating lung aeration at birth

article en

Abstract

• We adapted a 3-D adult lung morphometric model to represent the preterm newborn lung. • We modeled changing airway mechanics during lung aeration at birth with lumped elements. • Combining morphometry and airway mechanical models, we simulated lung aeration at birth. • An integrated circuit simulator allowed for the solution of the entire network in the time domain. • This approach may contribute to defining lung protective resuscitation strategies at birth. Lung aeration must rapidly develop at birth, but how to promote it without injuring the fragile lung is still unknown. Mathematical models simulating lung mechanics during this transition may help understand the underlying physiological mechanisms and design protective ventilation strategies. This study develops a morphologically-coherent computational lung model incorporating changing physical conditions during the transition from liquid-filled to gas-filled lungs. We adapted a 3-D morphological model of the adult airway tree adjusting airway dimensions, lung volume, and lung tissue mechanical properties. Changes in resistance, inertia, and compliance during aeration were modeled by considering the differing properties of fetal fluid versus air. The capillary pressure at the liquid–air interface was computed using Laplace equation. Terminal airway diameters increased with lung volume due to airway-parenchymal interdependence. An integrated circuit simulator solved the entire network in the time domain. The air volume entering the model at different applied pressures increased exponentially with time. With 30 cmH 2 O applied, lung volume reached total capacity after 15 s, matching lung aeration dynamics observed in animal models and human infants. In contrast, after the same time, at 15 cmH 2 O, lung volume was slightly above functional residual capacity, and at 10 cmH 2 O, it remained below. The proposed in-silico newborn lung model simulates lung aeration at birth, allowing observation of the airway emptying sequence and the heterogeneity of aeration at each time point. Integrating this model with comprehensive acinar models may aid in defining protective resuscitation ventilation strategies for recruiting the lung minimizing risk of injuries.

Journal of Applied BiomedicineVol. 45(4)
Boston University (US), Politecnico di Milano (IT)
Good health and well-being
Openalex Percentile: Top 32%
Neonatal Respiratory Health Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.