Comparison of Transient Mitigation through Synchronous Closing and Capacitor Switching in 150 kV Networks

This study addresses the challenge of transient voltage and current surges caused by capacitor bank switching in high-voltage transmission systems, which can compromise equipment integrity and system stability. The research focuses on optimizing the mitigation of these transients in a 150 kV transmission line using the synchronous closing breaker method. Simulations were conducted in MATLAB/Simulink using actual parameters provided by the power utility. To verify the accuracy of the Simulink model and its results, validation was performed in DIgSILENT PowerFactory by comparing steady-state voltage responses following capacitor switching. With the model validated, three operating scenarios were examined: no capacitor bank, conventional capacitor bank switching, and with the implementation of synchronous closing breakers. The synchronous closing method significantly reduced transient voltage and current magnitudes compared to conventional switching. These outcomes confirm the effectiveness of the synchronous closing breaker in minimizing transient disturbances. The findings contribute to the development of improved transient mitigation strategies and offer a practical reference for large-scale capacitor bank deployment, particularly in smart grid applications. This method provides a cost-effective and scalable approach for improving power quality in modern high-voltage transmission networks.

Institutions

Publication Details

Journal
International Journal of Electrical Energy and Power System Engineering
Published
2025-11-09
DOI
https://doi.org/10.31258/ijeepse.8.3.323-336
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Transient Mitigation through Synchronous Closing and Capacitor Switching in 150 kV Networks

International Journal of Electrical Energy and Power System Engineering
HVDC Systems and Fault Protection
article

Comparison of Transient Mitigation through Synchronous Closing and Capacitor Switching in 150 kV Networks

article en

Abstract

This study addresses the challenge of transient voltage and current surges caused by capacitor bank switching in high-voltage transmission systems, which can compromise equipment integrity and system stability. The research focuses on optimizing the mitigation of these transients in a 150 kV transmission line using the synchronous closing breaker method. Simulations were conducted in MATLAB/Simulink using actual parameters provided by the power utility. To verify the accuracy of the Simulink model and its results, validation was performed in DIgSILENT PowerFactory by comparing steady-state voltage responses following capacitor switching. With the model validated, three operating scenarios were examined: no capacitor bank, conventional capacitor bank switching, and with the implementation of synchronous closing breakers. The synchronous closing method significantly reduced transient voltage and current magnitudes compared to conventional switching. These outcomes confirm the effectiveness of the synchronous closing breaker in minimizing transient disturbances. The findings contribute to the development of improved transient mitigation strategies and offer a practical reference for large-scale capacitor bank deployment, particularly in smart grid applications. This method provides a cost-effective and scalable approach for improving power quality in modern high-voltage transmission networks.

International Journal of Electrical Energy and Power System EngineeringVol. 8(3)
NED University of Engineering and Technology (PK), Riau University (ID)
Universitas Riau
Affordable and clean energy
Openalex Percentile: Top 47%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparison of Transient Mitigation through Synchronous Closing and Capacitor Switching in 150 kV Networks · International Journal of Electrical Energy and Power System Engineering (2025) | TGRS Research Map | TGRS