Design and experimental validation of a novel additively manufactured stenosis model for neurointerventional training

Stenoses, or pathological narrowings of blood vessels, are significant risk factors for cardiovascular events. While various stenosis models exist for training purposes, they often present limitations for intracranial applications due to their size and inability to maintain vessel dilation after treatment. This paper presents the development and evaluation of a novel stenosis model specifically designed for compact, intracranial applications within the neurointerventional simulator HANNES. The model utilizes a C-shaped clip mechanism that selectively constricts an elastic vessel, incorporating a designed breaking point that ensures permanent vessel dilation upon reaching a critical pressure during balloon angioplasty. The model was manufactured using stereolithographic additive manufacturing and underwent experimental evaluation using a standard PTA balloon catheter. Results demonstrated reproducible burst pressures of 12 ± 1 bar, aligning with typical clinical parameters. X-ray imaging confirmed successful integration into the HANNES simulator, enabling realistic simulation of stenosis treatment procedures. Experiments showed that the developed stenosis model should be used with elastic silicone tubes connected to additively manufactured vessel models, as direct application to printed vessels either resulted in vessel wall damage during compression or insufficient constriction depending on the C-clip geometry. Based on these findings and the successful validation results, the model represents a reliable and reproducible platform for neurointerventional training, with its parametric design allowing adaptation to various clinical scenarios.

Publication Details

Journal
TUHH Open Research
Published
2025-06-02
DOI
https://doi.org/10.15480/882.16210
Primary Topic
Anatomy and Medical Technology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and experimental validation of a novel additively manufactured stenosis model for neurointerventional training

TUHH Open Research
Anatomy and Medical Technology
article

Design and experimental validation of a novel additively manufactured stenosis model for neurointerventional training

article en

Abstract

Stenoses, or pathological narrowings of blood vessels, are significant risk factors for cardiovascular events. While various stenosis models exist for training purposes, they often present limitations for intracranial applications due to their size and inability to maintain vessel dilation after treatment. This paper presents the development and evaluation of a novel stenosis model specifically designed for compact, intracranial applications within the neurointerventional simulator HANNES. The model utilizes a C-shaped clip mechanism that selectively constricts an elastic vessel, incorporating a designed breaking point that ensures permanent vessel dilation upon reaching a critical pressure during balloon angioplasty. The model was manufactured using stereolithographic additive manufacturing and underwent experimental evaluation using a standard PTA balloon catheter. Results demonstrated reproducible burst pressures of 12 ± 1 bar, aligning with typical clinical parameters. X-ray imaging confirmed successful integration into the HANNES simulator, enabling realistic simulation of stenosis treatment procedures. Experiments showed that the developed stenosis model should be used with elastic silicone tubes connected to additively manufactured vessel models, as direct application to printed vessels either resulted in vessel wall damage during compression or insufficient constriction depending on the C-clip geometry. Based on these findings and the successful validation results, the model represents a reliable and reproducible platform for neurointerventional training, with its parametric design allowing adaptation to various clinical scenarios.

TUHH Open Research
Good health and well-being
Openalex Percentile: Top 49%
Anatomy and Medical Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design and experimental validation of a novel additively manufactured stenosis model for neurointerventional training · TUHH Open Research (2025) | TGRS Research Map | TGRS