A Portable QCM-Based Biosensor-Incorporated Graphene Oxide for Point-of-Care Prostate Cancer Marker Detection

Prostate cancer remains one of the most prevalent malignancies among men worldwide, with late-stage diagnosis contributing significantly to mortality rates. In this study, we report the development of a graphene oxide (GO)-based QCM biosensor for the early and sensitive detection of Prostate Cancer Antigen 3 (PCA3), a biomarker with higher specificity than conventional PSA tests. The sensor interface was fabricated via a layer-by-layer approach of L-cysteine, GO, and a capture probe onto a gold electrode, resulting in enhanced surface area and biomolecular recognition capacity. Structural and morphological characterizations using XRD, FE-SEM, AFM, and FT-IR confirmed the successful and uniform integration of GO and functional layers. Optimization of fabrication parameters, including EDC-NHS activation time, capture probe concentration, and target incubation time, was performed to achieve maximum sensitivity and binding efficiency. The biosensor demonstrated a distinct, concentration-dependent frequency shift upon hybridization with PCA3 targets over a range of 1.00 fM to 1.00 μM, with a calculated limit of detection (LOD) of 0.268 nM and a rapid response time of 20 min. These results underscore the potential of GO-modified QCM platforms for highly sensitive, rapid, and portable diagnostics, not only for prostate cancer screening but also for broader clinical applications involving biomarkers.

Institutions

Publication Details

Journal
Technologies
Published
2025-11-24
DOI
https://doi.org/10.3390/technologies13120544
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Portable QCM-Based Biosensor-Incorporated Graphene Oxide for Point-of-Care Prostate Cancer Marker Detection

Technologies
Advanced biosensing and bioanalysis techniques
article

A Portable QCM-Based Biosensor-Incorporated Graphene Oxide for Point-of-Care Prostate Cancer Marker Detection

article en

Abstract

Prostate cancer remains one of the most prevalent malignancies among men worldwide, with late-stage diagnosis contributing significantly to mortality rates. In this study, we report the development of a graphene oxide (GO)-based QCM biosensor for the early and sensitive detection of Prostate Cancer Antigen 3 (PCA3), a biomarker with higher specificity than conventional PSA tests. The sensor interface was fabricated via a layer-by-layer approach of L-cysteine, GO, and a capture probe onto a gold electrode, resulting in enhanced surface area and biomolecular recognition capacity. Structural and morphological characterizations using XRD, FE-SEM, AFM, and FT-IR confirmed the successful and uniform integration of GO and functional layers. Optimization of fabrication parameters, including EDC-NHS activation time, capture probe concentration, and target incubation time, was performed to achieve maximum sensitivity and binding efficiency. The biosensor demonstrated a distinct, concentration-dependent frequency shift upon hybridization with PCA3 targets over a range of 1.00 fM to 1.00 μM, with a calculated limit of detection (LOD) of 0.268 nM and a rapid response time of 20 min. These results underscore the potential of GO-modified QCM platforms for highly sensitive, rapid, and portable diagnostics, not only for prostate cancer screening but also for broader clinical applications involving biomarkers.

TechnologiesVol. 13(12)
Suranaree University of Technology (TH)
Suranaree University of Technology
Good health and well-being
Openalex Percentile: Top 42%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.