Transient Recovery Voltage Analysis of a 500-kV Transmission Line with Additional Series Reactors

This study investigates the impact of series reactor installation on transient recovery voltage (TRV) and the rate of rise of recovery voltage (RRRV) in the 500 kV Suralaya–Suralaya Baru transmission line within the projected 2030 Java–Madura–Bali (JAMALI) power system. Using data from the PLN RUPTL 2021–2030 [21], the research evaluates how series reactors influence TRV and RRRV during a single line-to-ground or short-line fault occurring 5% from the Suralaya line. Simulations were conducted in DIgSILENT PowerFactory using detailed transmission line modeling that incorporates line coupling and stray capacitance, with model validation performed through power flow and short-circuit comparisons. Two scenarios, before and after the installation of series reactors, were assessed. Prior to installation, TRV was 872.9 kV and RRRV was 2.14 kV/µs, while after installation TRV increased to 922.2 kV and RRRV increased to 11.9 kV/µs. Although the TRV remains within IEEE Std C37.011-2019 limits [11], the RRRV exceeds the standard threshold, indicating the need for mitigation. The study’s novelty lies in developing a detailed Java–Madura–Bali system model in PowerFactory and applying network reduction to improve simulation efficiency. As the effects of series reactors on TRV and RRRV in this system have not been previously examined, the findings provide essential insights for ensuring circuit breaker reliability and supporting future high-voltage system planning.

Institutions

Publication Details

Journal
International Journal of Electrical Energy and Power System Engineering
Published
2025-11-19
DOI
https://doi.org/10.31258/ijeepse.8.3.379-390
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transient Recovery Voltage Analysis of a 500-kV Transmission Line with Additional Series Reactors

International Journal of Electrical Energy and Power System Engineering
HVDC Systems and Fault Protection
article

Transient Recovery Voltage Analysis of a 500-kV Transmission Line with Additional Series Reactors

article en

Abstract

This study investigates the impact of series reactor installation on transient recovery voltage (TRV) and the rate of rise of recovery voltage (RRRV) in the 500 kV Suralaya–Suralaya Baru transmission line within the projected 2030 Java–Madura–Bali (JAMALI) power system. Using data from the PLN RUPTL 2021–2030 [21], the research evaluates how series reactors influence TRV and RRRV during a single line-to-ground or short-line fault occurring 5% from the Suralaya line. Simulations were conducted in DIgSILENT PowerFactory using detailed transmission line modeling that incorporates line coupling and stray capacitance, with model validation performed through power flow and short-circuit comparisons. Two scenarios, before and after the installation of series reactors, were assessed. Prior to installation, TRV was 872.9 kV and RRRV was 2.14 kV/µs, while after installation TRV increased to 922.2 kV and RRRV increased to 11.9 kV/µs. Although the TRV remains within IEEE Std C37.011-2019 limits [11], the RRRV exceeds the standard threshold, indicating the need for mitigation. The study’s novelty lies in developing a detailed Java–Madura–Bali system model in PowerFactory and applying network reduction to improve simulation efficiency. As the effects of series reactors on TRV and RRRV in this system have not been previously examined, the findings provide essential insights for ensuring circuit breaker reliability and supporting future high-voltage system planning.

International Journal of Electrical Energy and Power System EngineeringVol. 8(3)
Bandung Institute of Technology (ID), National Grid (United Kingdom) (GB), Siliwangi University (ID), Riau University (ID)
Affordable and clean energy
Openalex Percentile: Top 48%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Transient Recovery Voltage Analysis of a 500-kV Transmission Line with Additional Series Reactors · International Journal of Electrical Energy and Power System Engineering (2025) | TGRS Research Map | TGRS