Investigation of the effectiveness of point-of-use (POU) water dispensers in reducing lead and nickel levels in drinking water

• POU water dispensers were investigated as potential sources of metal contamination. • Effectiveness of POU dispensers in reducing drinking water Ni and Pb was explored. • Stainless steel components and solders were main sources of Ni and Pb respectively. • Removal efficiency was enhanced at higher metal concentrations. • The dispensers effectively reduced Pb but showed limited efficiency in Ni removal. While trusted by consumers for safe drinking water, the effectiveness of point-of-use (POU) dispensers in reducing health-relevant heavy metals, such as lead (Pb) and nickel (Ni), and the potential of metal leaching from their internal components remain largely unexplored. This study conducts a detailed investigation of individual component within POU dispensers and their contribution to either the removal or release of Pb and Ni under controlled experimental conditions. Experiments were conducted using synthesized tap water as source water across three scenarios: clean water (no Pb or Ni), low spike (Pb: 10 μg/L, Ni: 20 μg/L), and high spike (Pb and Ni: 100 μg/L). Water samples collected from five downstream points, including post-filtration, storage, transfer, and outlet units, revealed detectable levels of Pb and Ni even under clean water conditions, indicating that component units could be potential sources. Pb levels were effectively reduced to below the local regulatory standard of 10 μg/L across most scenarios, except in hot water systems. Conversely, Ni concentrations frequently surpassed the local regulatory standard of 20 μg/L, particularly in hot water storage and outlet. Stainless steel components and solders were determined to be the sources of Ni and Pb respectively. Our findings recommend the need for a third-party monitoring of the POU dispensers and offer valuable insights to inform evidence-based improvements in material selection and testing, thereby ensuring the safety of drinking water.

Institutions

Publication Details

Journal
Water Research X
Published
2025-11-23
DOI
https://doi.org/10.1016/j.wroa.2025.100458
Primary Topic
Water Treatment and Disinfection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of the effectiveness of point-of-use (POU) water dispensers in reducing lead and nickel levels in drinking water

Water Research X
Water Treatment and Disinfection
article

Investigation of the effectiveness of point-of-use (POU) water dispensers in reducing lead and nickel levels in drinking water

article en

Abstract

• POU water dispensers were investigated as potential sources of metal contamination. • Effectiveness of POU dispensers in reducing drinking water Ni and Pb was explored. • Stainless steel components and solders were main sources of Ni and Pb respectively. • Removal efficiency was enhanced at higher metal concentrations. • The dispensers effectively reduced Pb but showed limited efficiency in Ni removal. While trusted by consumers for safe drinking water, the effectiveness of point-of-use (POU) dispensers in reducing health-relevant heavy metals, such as lead (Pb) and nickel (Ni), and the potential of metal leaching from their internal components remain largely unexplored. This study conducts a detailed investigation of individual component within POU dispensers and their contribution to either the removal or release of Pb and Ni under controlled experimental conditions. Experiments were conducted using synthesized tap water as source water across three scenarios: clean water (no Pb or Ni), low spike (Pb: 10 μg/L, Ni: 20 μg/L), and high spike (Pb and Ni: 100 μg/L). Water samples collected from five downstream points, including post-filtration, storage, transfer, and outlet units, revealed detectable levels of Pb and Ni even under clean water conditions, indicating that component units could be potential sources. Pb levels were effectively reduced to below the local regulatory standard of 10 μg/L across most scenarios, except in hot water systems. Conversely, Ni concentrations frequently surpassed the local regulatory standard of 20 μg/L, particularly in hot water storage and outlet. Stainless steel components and solders were determined to be the sources of Ni and Pb respectively. Our findings recommend the need for a third-party monitoring of the POU dispensers and offer valuable insights to inform evidence-based improvements in material selection and testing, thereby ensuring the safety of drinking water.

Water Research XVol. 30
Chaoyang University of Technology (TW), National Taiwan University (TW), National Ilan University (TW)
Clean water and sanitation
Openalex Percentile: Top 39%
Water Treatment and Disinfection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Investigation of the effectiveness of point-of-use (POU) water dispensers in reducing lead and nickel levels in drinking water · Water Research X (2025) | TGRS Research Map | TGRS