Clinical assessment and acceptance criteria for continuous glucose monitoring (CGM) system performance: A proposed guideline by the IFCC Working Group on CGM.

Continuous glucose monitoring (CGM) systems are essential tools for modern diabetes care. However, the assessment of their analytical performance has been hindered by a lack of standardization. This poses challenges for the field, as the choice of study procedures and evaluation methods can influence the observed performance, further complicating the comparisons between CGM systems and confounding the interpretation and use of CGM metrics as research outcomes. To address this issue, the Working Group on CGM of the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) has developed a comprehensive guideline for the clinical assessment of CGM systems. The guideline defines requirements for study design and procedures, characteristics of comparator measurements, minimum requirements for accuracy, and performance characterization.

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-11-16
DOI
https://doi.org/10.48620/92537
Primary Topic
Diabetes Management and Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical assessment and acceptance criteria for continuous glucose monitoring (CGM) system performance: A proposed guideline by the IFCC Working Group on CGM.

Open Access CRIS of the University of Bern
Diabetes Management and Research
article

Clinical assessment and acceptance criteria for continuous glucose monitoring (CGM) system performance: A proposed guideline by the IFCC Working Group on CGM.

article en

Abstract

Continuous glucose monitoring (CGM) systems are essential tools for modern diabetes care. However, the assessment of their analytical performance has been hindered by a lack of standardization. This poses challenges for the field, as the choice of study procedures and evaluation methods can influence the observed performance, further complicating the comparisons between CGM systems and confounding the interpretation and use of CGM metrics as research outcomes. To address this issue, the Working Group on CGM of the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) has developed a comprehensive guideline for the clinical assessment of CGM systems. The guideline defines requirements for study design and procedures, characteristics of comparator measurements, minimum requirements for accuracy, and performance characterization.

Open Access CRIS of the University of Bern
Diabetes Australia (AU)
Partnerships for the goals
Openalex Percentile: Top 36%
Diabetes Management and Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Clinical assessment and acceptance criteria for continuous glucose monitoring (CGM) system performance: A proposed guideline by the IFCC Working Group on CGM. · Open Access CRIS of the University of Bern (2025) | TGRS Research Map | TGRS