Breakage in Bifacial PV Modules

This work presents the occurrence of glass cracking in bifacial photovoltaic modules installed at the São Paulo campus of University of São Paulo. One of the systems consists of 78 bifacial modules (545 Wp) arranged in six strings connected to a 35 kW inverter with a single-axis tracker. Within the first month of operation, two modules exhibited cracks in the rear glass. Over the following months the number of PV modules with cracks increased to 20 (25.6%) in 14 months. To gain understanding of the reasons for the glass cracking events, after discussions with the supplier and manufacturer, a second system with 30 modules (545 Wp) of the same maker and model was installed on a fixed-tilt structure. In the fixed-tilt system cracks were observed in nine modules after 10 months of installation (30%). This study documents the cracking patterns in both systems and compares their occurrence to better understand the underlying causes.

Publication Details

Journal
EU PVSEC
Published
2025-11-20
DOI
https://doi.org/10.4229/eupvsec2025/3av.2.18
Primary Topic
Photovoltaic System Optimization Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Breakage in Bifacial PV Modules

EU PVSEC
Photovoltaic System Optimization Techniques
article

Breakage in Bifacial PV Modules

article en

Abstract

This work presents the occurrence of glass cracking in bifacial photovoltaic modules installed at the São Paulo campus of University of São Paulo. One of the systems consists of 78 bifacial modules (545 Wp) arranged in six strings connected to a 35 kW inverter with a single-axis tracker. Within the first month of operation, two modules exhibited cracks in the rear glass. Over the following months the number of PV modules with cracks increased to 20 (25.6%) in 14 months. To gain understanding of the reasons for the glass cracking events, after discussions with the supplier and manufacturer, a second system with 30 modules (545 Wp) of the same maker and model was installed on a fixed-tilt structure. In the fixed-tilt system cracks were observed in nine modules after 10 months of installation (30%). This study documents the cracking patterns in both systems and compares their occurrence to better understand the underlying causes.

EU PVSEC
Openalex Percentile: Top 61%
Photovoltaic System Optimization Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.