BIPV Simulation with Conventional Tools and Models; Do We Need More Accuracy?

The present work compares two simulation tools, SAM and PVsyst, to assess their suitability in analysing the behaviour of BIPV systems, with special focus on their management of the effect of shading losses in energy output estimations, in addition to module temperature. The simulations are performed for Building 42 in CIEMAT headquarters, which was renovated in 2017 with monitored BIPV systems on the east, south and west façades. The shading tools in both software are capable of modelling the environment through simple geometric elements; moreover, PVsyst also allows the use of an external 3D file that can simplify the process. The results of this study manifest that the 3D scene method used to assess the effect of shading can have a strong impact on the reliability of energy output estimations. When using the same 3D scenes through their built-in tools, SAM shows better performance than PVsyst. In contrast, PVsyst energy output results improve significantly when using an imported 3D digital asset exchange file derived from Light Detection and Ranging data. This discrepancy in results remarks the need for special attention regarding the configuration and modelling of shading elements, which requires future work to better understand the simulation methods in each tool.

Publication Details

Journal
EU PVSEC
Published
2025-11-20
DOI
https://doi.org/10.4229/eupvsec2025/4bv.4.5
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

BIPV Simulation with Conventional Tools and Models; Do We Need More Accuracy?

EU PVSEC
Building Energy and Comfort Optimization
article

BIPV Simulation with Conventional Tools and Models; Do We Need More Accuracy?

article en

Abstract

The present work compares two simulation tools, SAM and PVsyst, to assess their suitability in analysing the behaviour of BIPV systems, with special focus on their management of the effect of shading losses in energy output estimations, in addition to module temperature. The simulations are performed for Building 42 in CIEMAT headquarters, which was renovated in 2017 with monitored BIPV systems on the east, south and west façades. The shading tools in both software are capable of modelling the environment through simple geometric elements; moreover, PVsyst also allows the use of an external 3D file that can simplify the process. The results of this study manifest that the 3D scene method used to assess the effect of shading can have a strong impact on the reliability of energy output estimations. When using the same 3D scenes through their built-in tools, SAM shows better performance than PVsyst. In contrast, PVsyst energy output results improve significantly when using an imported 3D digital asset exchange file derived from Light Detection and Ranging data. This discrepancy in results remarks the need for special attention regarding the configuration and modelling of shading elements, which requires future work to better understand the simulation methods in each tool.

EU PVSEC
Affordable and clean energy
Openalex Percentile: Top 46%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.