Optimizing nanowell biosensor fabrication: Evaluation of metal deposition and oxide layer modification

This study presents a comparative evaluation of two nanowell-based biosensor fabrication methods designed to improve sensing performance and device reliability. The conventional process employs electron beam (e-beam) evaporation for metal deposition and aluminum oxide (Al 2 O 3 ) as the insulating layer, while the modified approach utilizes the sputtering method for metal deposition and hafnium oxide (HfO 2 ) as the insulating layer, respectively. Both fabrication methods were used to construct nanowell impedance biosensors for detecting interleukin-6 (IL-6) at concentrations ranging from 10 nM to 10 fM. Electrochemical impedance spectroscopy (EIS) was performed in a two-electrode configuration using an AC excitation of 10 mV across a frequency range of 1 Hz to 5 MHz. The Sputtered/HfO 2 biosensors exhibited improved electrical insulation, enhanced step coverage, and reduced device failure due to short or open circuits. These improvements resulted in a higher baseline response, reduced voltage drift, and enhanced sensitivity, achieving a limit of detection (LOD) of 7.8 fM compared to 15.5 fM for the E-beam/Al 2 O 3 sensors. The results demonstrate that optimized fabrication using sputtering and HfO 2 significantly enhances biosensor reproducibility and detection performance, supporting its application in scalable, label-free diagnostic platforms. • Modified biosensor uses sputtering and HfO 2 for improved performance. • Enhanced sensitivity enables IL-6 detection down to 7.8 fM concentrations. • Sputtered/HfO 2 sensors show 81% higher baseline response in 1× PBS. • Voltage drift correction boosts signal accuracy for protein detection. • Improved fabrication yields more reliable sensors for scalable production.

Institutions

Publication Details

Journal
Biosensors and Bioelectronics X
Published
2025-11-22
DOI
https://doi.org/10.1016/j.biosx.2025.100713
Primary Topic
Nanowire Synthesis and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing nanowell biosensor fabrication: Evaluation of metal deposition and oxide layer modification

Biosensors and Bioelectronics X
Nanowire Synthesis and Applications
article

Optimizing nanowell biosensor fabrication: Evaluation of metal deposition and oxide layer modification

article en

Abstract

This study presents a comparative evaluation of two nanowell-based biosensor fabrication methods designed to improve sensing performance and device reliability. The conventional process employs electron beam (e-beam) evaporation for metal deposition and aluminum oxide (Al 2 O 3 ) as the insulating layer, while the modified approach utilizes the sputtering method for metal deposition and hafnium oxide (HfO 2 ) as the insulating layer, respectively. Both fabrication methods were used to construct nanowell impedance biosensors for detecting interleukin-6 (IL-6) at concentrations ranging from 10 nM to 10 fM. Electrochemical impedance spectroscopy (EIS) was performed in a two-electrode configuration using an AC excitation of 10 mV across a frequency range of 1 Hz to 5 MHz. The Sputtered/HfO 2 biosensors exhibited improved electrical insulation, enhanced step coverage, and reduced device failure due to short or open circuits. These improvements resulted in a higher baseline response, reduced voltage drift, and enhanced sensitivity, achieving a limit of detection (LOD) of 7.8 fM compared to 15.5 fM for the E-beam/Al 2 O 3 sensors. The results demonstrate that optimized fabrication using sputtering and HfO 2 significantly enhances biosensor reproducibility and detection performance, supporting its application in scalable, label-free diagnostic platforms. • Modified biosensor uses sputtering and HfO 2 for improved performance. • Enhanced sensitivity enables IL-6 detection down to 7.8 fM concentrations. • Sputtered/HfO 2 sensors show 81% higher baseline response in 1× PBS. • Voltage drift correction boosts signal accuracy for protein detection. • Improved fabrication yields more reliable sensors for scalable production.

Biosensors and Bioelectronics XVol. 27
Rutgers, The State University of New Jersey (US)
Affordable and clean energy
Openalex Percentile: Top 49%
Nanowire Synthesis and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.