Variations in Erythrocyte Count and Hemoglobin Levels in Blood Samples Collected Using Conventional Anticoagulants and Vacutainers with Different Secondary Homogenization Techniques

The choice of anticoagulants and the methods of homogenization are critical pre-analytical steps that can significantly influence the accuracy of laboratory results. This study aims to assess the differences in erythrocyte count and hemoglobin levels among blood samples processed with conventional anticoagulants and Vacutainer tubes, taking into account variations in secondary homogenization techniques. A laboratory experimental design was employed, utilizing 32 blood samples acquired from eight participants. The analysis was conducted using an automated hematology analyzer. Data were subjected to a Paired T-Test, indicating no significant differences in erythrocyte counts (p=0.617) and hemoglobin levels (p=0.510) between conventional EDTA samples that were homogenized four times and those homogenized eight times. However, a significant difference was noted in erythrocyte counts (p=0.018), while hemoglobin levels remained unaffected (p=0.393) in EDTA vacutainer samples subjected to four versus eight rounds of secondary homogenization. Additionally, a significant difference was found in both erythrocyte counts (p = 0.008) and hemoglobin levels (p < 0.0001) between conventional EDTA samples and those subjected to four rounds of secondary homogenization using vacutainers. Similarly, there was a significant difference in erythrocyte counts (p = 0.006) and hemoglobin levels (p = 0.014) between conventional EDTA samples and Vacutainer samples that underwent eight rounds of homogenization. Keywords: Blood Specimen Collection; EDTA; Erythrocyte; Hemoglobin; Secondary Homogenization

Institutions

Publication Details

Journal
Medical Technology and Public Health Journal
Published
2025-11-20
DOI
https://doi.org/10.33086/mtphj.v9i2.7006
Primary Topic
Clinical Laboratory Practices and Quality Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Variations in Erythrocyte Count and Hemoglobin Levels in Blood Samples Collected Using Conventional Anticoagulants and Vacutainers with Different Secondary Homogenization Techniques

Medical Technology and Public Health Journal
Clinical Laboratory Practices and Quality Control
article

Variations in Erythrocyte Count and Hemoglobin Levels in Blood Samples Collected Using Conventional Anticoagulants and Vacutainers with Different Secondary Homogenization Techniques

article en

Abstract

The choice of anticoagulants and the methods of homogenization are critical pre-analytical steps that can significantly influence the accuracy of laboratory results. This study aims to assess the differences in erythrocyte count and hemoglobin levels among blood samples processed with conventional anticoagulants and Vacutainer tubes, taking into account variations in secondary homogenization techniques. A laboratory experimental design was employed, utilizing 32 blood samples acquired from eight participants. The analysis was conducted using an automated hematology analyzer. Data were subjected to a Paired T-Test, indicating no significant differences in erythrocyte counts (p=0.617) and hemoglobin levels (p=0.510) between conventional EDTA samples that were homogenized four times and those homogenized eight times. However, a significant difference was noted in erythrocyte counts (p=0.018), while hemoglobin levels remained unaffected (p=0.393) in EDTA vacutainer samples subjected to four versus eight rounds of secondary homogenization. Additionally, a significant difference was found in both erythrocyte counts (p = 0.008) and hemoglobin levels (p < 0.0001) between conventional EDTA samples and those subjected to four rounds of secondary homogenization using vacutainers. Similarly, there was a significant difference in erythrocyte counts (p = 0.006) and hemoglobin levels (p = 0.014) between conventional EDTA samples and Vacutainer samples that underwent eight rounds of homogenization. Keywords: Blood Specimen Collection; EDTA; Erythrocyte; Hemoglobin; Secondary Homogenization

Medical Technology and Public Health JournalVol. 9(2)
Universitas Muhammadiyah Sidoarjo (ID)
Openalex Percentile: Top 39%
Clinical Laboratory Practices and Quality Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Variations in Erythrocyte Count and Hemoglobin Levels in Blood Samples Collected Using Conventional Anticoagulants and Vacutainers with Different Secondary Homogenization Techniques · Medical Technology and Public Health Journal (2025) | TGRS Research Map | TGRS