Development and validation of q-absorbance ratio method for simultaneous quantification of linagliptin and metformin HCl in synthetic mixture and combined tablets

The present study aims to develop and validate simple, cost effective Q-Absorbance Ratio Method for simultaneous quantification of Linagliptin (LIN) and Metformin HCl (MET). The proposed medium Acetonitrile: Methanol: Distilled Water at 1:1:1 (Solvent Blend) identified λmax 235nm for MET, 298nm for LIN and Isobestic point at 231.7nm for Q-Absorbance Ratio Method. The validation follows ICH Q2(R1) guidelines, demonstrating excellent linearity, accuracy, precision and sensitivity (LOD and LOQ) for LIN and MET. The developed method was successfully applied to a synthetic mixture and marketed formulation, showing % recovery within the acceptable limit with % RSD was less than 2.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-10-31
DOI
https://doi.org/10.5281/zenodo.17617316
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and validation of q-absorbance ratio method for simultaneous quantification of linagliptin and metformin HCl in synthetic mixture and combined tablets

Zenodo (CERN European Organization for Nuclear Research)
Analytical Methods in Pharmaceuticals
article

Development and validation of q-absorbance ratio method for simultaneous quantification of linagliptin and metformin HCl in synthetic mixture and combined tablets

article en

Abstract

The present study aims to develop and validate simple, cost effective Q-Absorbance Ratio Method for simultaneous quantification of Linagliptin (LIN) and Metformin HCl (MET). The proposed medium Acetonitrile: Methanol: Distilled Water at 1:1:1 (Solvent Blend) identified λmax 235nm for MET, 298nm for LIN and Isobestic point at 231.7nm for Q-Absorbance Ratio Method. The validation follows ICH Q2(R1) guidelines, demonstrating excellent linearity, accuracy, precision and sensitivity (LOD and LOQ) for LIN and MET. The developed method was successfully applied to a synthetic mixture and marketed formulation, showing % recovery within the acceptable limit with % RSD was less than 2.

Zenodo (CERN European Organization for Nuclear Research)
University of Agricultural Sciences Raichur (IN)
Openalex Percentile: Top 47%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.