Influence of FRP Fan Anchors on the Tensile Capacity of Quadriaxial Fabrics

Undesirable shear failures can be detrimental for the seismic performance of existing RC buildings, particularly at the beam–column joint (BCJ). Experimental tests and analytical studies demonstrated that fiber-reinforced polymer (FRP) materials are effective as local strengthening solutions, enhancing shear capacity and preventing the joint panel shear failures. Furthermore, they have the advantages of rapid and minimally invasive application. Despite these benefits, debonding at the FRP–concrete interface limits their effectiveness to working strains significantly lower than ultimate capacity. Mechanical FRP fan anchors have shown a great potential in avoiding the end-debonding and increasing the strength of FRP systems. However, to date, experimental tests on quadriaxial fabrics, commonly used in the seismic strengthening of BCJs, anchored with FRP fan are missing. This study investigates the influence of FRP fan anchors on the tensile capacity of FRP quadriaxial fabrics. The experimental results of an extensive testing campaign in terms of strength and strain response for anchored and unanchored specimens are presented and discussed along with a comparison with predictions obtained using available capacity models.

Institutions

Publication Details

Journal
Journal of Composites for Construction
Published
2025-11-13
DOI
https://doi.org/10.1061/jccof2.cceng-5363
Citations
2
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
2.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of FRP Fan Anchors on the Tensile Capacity of Quadriaxial Fabrics

2 citations
Journal of Composites for Construction
Structural Behavior of Reinforced Concrete
2.01
article

Influence of FRP Fan Anchors on the Tensile Capacity of Quadriaxial Fabrics

article en
2 citations

Abstract

Undesirable shear failures can be detrimental for the seismic performance of existing RC buildings, particularly at the beam–column joint (BCJ). Experimental tests and analytical studies demonstrated that fiber-reinforced polymer (FRP) materials are effective as local strengthening solutions, enhancing shear capacity and preventing the joint panel shear failures. Furthermore, they have the advantages of rapid and minimally invasive application. Despite these benefits, debonding at the FRP–concrete interface limits their effectiveness to working strains significantly lower than ultimate capacity. Mechanical FRP fan anchors have shown a great potential in avoiding the end-debonding and increasing the strength of FRP systems. However, to date, experimental tests on quadriaxial fabrics, commonly used in the seismic strengthening of BCJs, anchored with FRP fan are missing. This study investigates the influence of FRP fan anchors on the tensile capacity of FRP quadriaxial fabrics. The experimental results of an extensive testing campaign in terms of strength and strain response for anchored and unanchored specimens are presented and discussed along with a comparison with predictions obtained using available capacity models.

Journal of Composites for ConstructionVol. 30(1)
University of Sannio (IT), University of Naples Federico II (IT)
Sustainable cities and communities
Openalex Percentile: Top 12%
Structural Behavior of Reinforced Concrete
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.