A probe-corrected loop-mediated isothermal amplification–lateral flow assay platform for highly specific, point-of-care detection of Brucella abortus DNA

Brucellosis, primarily caused by Brucella abortus , is a significant zoonotic disease affecting cattle worldwide. Accurate and early detection of B. abortus is crucial for effective disease control; however, existing diagnostic methods are limited by low sensitivity, lengthy processing times, and impracticality for field use. In this study, we developed a novel loop-mediated isothermal amplification–lateral flow assay (LAMP–LFA) platform that integrates a biotinylated DNA probe and fluorescein isothiocyanate–labeled primers to detect BruAb2_0168 of B. abortus . Unlike conventional LAMP-based diagnostics, our platform does not entirely prevent nonspecific amplification. Instead, it distinguishes target-specific products from nonspecific products by selective probe hybridization. Only true-positive amplicons hybridize with the probe to produce visible signals on the LFA strip, effectively eliminating the false-positive interpretations that typically limit the diagnostic reliability of LAMP-based methods. We optimized the amplification conditions (temperature, time, and primer/probe concentration) and LFA strip design to ensure high performance. Our platform achieved a detection limit of ≥8.85 CFU/mL, and no cross-reactivity was observed with other common pathogens. Validation using 20 whole-blood samples demonstrated that its diagnostic performance was statistically equivalent to that of polymerase chain reaction (area under the curve = 1.0, McNemar's p > 0.05). The assay reports results within 1 h, requires no instrumentation, and is suitable for use in field or resource-limited settings. Overall, our probe-corrected LAMP–LFA platform offers enhanced specificity, operational simplicity, and field-deployable utility, making it a valuable alternative for rapid and accurate B. abortus diagnosis. • Novel LAMP–LFA enabled on-site detection of Brucella abortus DNA in blood samples. • Achieved a detection limit of 8.85 CFU/mL with high sensitivity and specificity. • Integrated biotinylated DNA probes and anti-FITC antibodies for enhanced accuracy. • Validated LAMP–LFA's accuracy comparable to PCR in whole-blood samples (AUC = 1.0). • Enables early detection and control of brucellosis in resource-limited settings.

Institutions

Publication Details

Journal
Microchemical Journal
Published
2025-11-11
DOI
https://doi.org/10.1016/j.microc.2025.116153
Primary Topic
Brucella: diagnosis, epidemiology, treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A probe-corrected loop-mediated isothermal amplification–lateral flow assay platform for highly specific, point-of-care detection of Brucella abortus DNA

Microchemical Journal
Brucella: diagnosis, epidemiology, treatment
article

A probe-corrected loop-mediated isothermal amplification–lateral flow assay platform for highly specific, point-of-care detection of Brucella abortus DNA

article en

Abstract

Brucellosis, primarily caused by Brucella abortus , is a significant zoonotic disease affecting cattle worldwide. Accurate and early detection of B. abortus is crucial for effective disease control; however, existing diagnostic methods are limited by low sensitivity, lengthy processing times, and impracticality for field use. In this study, we developed a novel loop-mediated isothermal amplification–lateral flow assay (LAMP–LFA) platform that integrates a biotinylated DNA probe and fluorescein isothiocyanate–labeled primers to detect BruAb2_0168 of B. abortus . Unlike conventional LAMP-based diagnostics, our platform does not entirely prevent nonspecific amplification. Instead, it distinguishes target-specific products from nonspecific products by selective probe hybridization. Only true-positive amplicons hybridize with the probe to produce visible signals on the LFA strip, effectively eliminating the false-positive interpretations that typically limit the diagnostic reliability of LAMP-based methods. We optimized the amplification conditions (temperature, time, and primer/probe concentration) and LFA strip design to ensure high performance. Our platform achieved a detection limit of ≥8.85 CFU/mL, and no cross-reactivity was observed with other common pathogens. Validation using 20 whole-blood samples demonstrated that its diagnostic performance was statistically equivalent to that of polymerase chain reaction (area under the curve = 1.0, McNemar's p > 0.05). The assay reports results within 1 h, requires no instrumentation, and is suitable for use in field or resource-limited settings. Overall, our probe-corrected LAMP–LFA platform offers enhanced specificity, operational simplicity, and field-deployable utility, making it a valuable alternative for rapid and accurate B. abortus diagnosis. • Novel LAMP–LFA enabled on-site detection of Brucella abortus DNA in blood samples. • Achieved a detection limit of 8.85 CFU/mL with high sensitivity and specificity. • Integrated biotinylated DNA probes and anti-FITC antibodies for enhanced accuracy. • Validated LAMP–LFA's accuracy comparable to PCR in whole-blood samples (AUC = 1.0). • Enables early detection and control of brucellosis in resource-limited settings.

Microchemical JournalVol. 219
Gyeongsang National University (KR), Gwangju Institute of Science and Technology (KR), Korea Food Research Institute (KR)
Openalex Percentile: Top 35%
Brucella: diagnosis, epidemiology, treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.