Impact of left atrial anatomy on pulmonary vein isolation with cryoballoon ablation: Insights from the randomized controlled COMPARE CRYO study.

Background Cryoballoon ablation is an established therapy for pulmonary vein (PV) isolation (PVI).Objective This study aimed to explore whether specific left atrial anatomical features are associated with both first-pass PVI success and long-term outcomes after cryoballoon ablation using 2 different cryoablation systems.Methods Left atrial reconstructions of patients with paroxysmal atrial fibrillation were analyzed. PVI was performed using either the Medtronic (Minneapolis, MN) Arctic Front Advance or the Boston Scientific (Marlborough, MA) POLARx cryoablation catheter. Anatomical features were assessed to predict first-pass PVI success after a single application and long-term outcomes on the basis of implantable cardiac monitor recordings.Results A total of 191 patients were enrolled (mean age 63.0 ± 9.8 years; 58 (30%) women). First-pass PVI was achieved in 69% of all procedures. Female sex was significantly associated with reduced first-pass isolation success, limited to the right superior PV (odds ratio [OR] 0.50; 95% confidence interval [CI] 0.26-0.97; P = .04). Anatomical predictors of failure of first-pass PVI included the absence of an orthogonal orientation of the left superior PV (OR 0.20; 95% CI 0.05-0.88; P = .033) and the left inferior PV (OR 0.36; 95% CI 0.13-0.99; P = .047) as well as the presence of a right middle PV for the right superior PV (OR 3.58; 95% CI 1.18-10.9; P = .024). The absence of an orthogonal orientation of the left superior PV was associated with atrial tachyarrhythmia recurrence (OR 4.12; 95% CI 1.90-9.11; P < .001).Conclusion The absence of an orthogonal orientation of the left-sided PVs was significantly associated with lower first-pass isolation rates and a higher risk of recurrence. These findings highlight the importance of preprocedural anatomical assessment to identify potential challenges and tailor ablation strategies.

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-10-01
DOI
https://doi.org/10.48620/92286
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of left atrial anatomy on pulmonary vein isolation with cryoballoon ablation: Insights from the randomized controlled COMPARE CRYO study.

Open Access CRIS of the University of Bern
Atrial Fibrillation Management and Outcomes
article

Impact of left atrial anatomy on pulmonary vein isolation with cryoballoon ablation: Insights from the randomized controlled COMPARE CRYO study.

article en

Abstract

Background Cryoballoon ablation is an established therapy for pulmonary vein (PV) isolation (PVI).Objective This study aimed to explore whether specific left atrial anatomical features are associated with both first-pass PVI success and long-term outcomes after cryoballoon ablation using 2 different cryoablation systems.Methods Left atrial reconstructions of patients with paroxysmal atrial fibrillation were analyzed. PVI was performed using either the Medtronic (Minneapolis, MN) Arctic Front Advance or the Boston Scientific (Marlborough, MA) POLARx cryoablation catheter. Anatomical features were assessed to predict first-pass PVI success after a single application and long-term outcomes on the basis of implantable cardiac monitor recordings.Results A total of 191 patients were enrolled (mean age 63.0 ± 9.8 years; 58 (30%) women). First-pass PVI was achieved in 69% of all procedures. Female sex was significantly associated with reduced first-pass isolation success, limited to the right superior PV (odds ratio [OR] 0.50; 95% confidence interval [CI] 0.26-0.97; P = .04). Anatomical predictors of failure of first-pass PVI included the absence of an orthogonal orientation of the left superior PV (OR 0.20; 95% CI 0.05-0.88; P = .033) and the left inferior PV (OR 0.36; 95% CI 0.13-0.99; P = .047) as well as the presence of a right middle PV for the right superior PV (OR 3.58; 95% CI 1.18-10.9; P = .024). The absence of an orthogonal orientation of the left superior PV was associated with atrial tachyarrhythmia recurrence (OR 4.12; 95% CI 1.90-9.11; P < .001).Conclusion The absence of an orthogonal orientation of the left-sided PVs was significantly associated with lower first-pass isolation rates and a higher risk of recurrence. These findings highlight the importance of preprocedural anatomical assessment to identify potential challenges and tailor ablation strategies.

Open Access CRIS of the University of Bern
Openalex Percentile: Top 35%
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.