Zn ion-implanted absorbable Fe for improved cytocompatibility and mitigated neointimal hyperplasia

Abstract Ultrathin strut Fe-based scaffolds have made significant progress in the field of vascular interventional devices, but the issues of slow degradation and insufficient biocompatibility at the cell/material interface remain unresolved. This study prepared a functionalized surface on Fe by Zn ion implantation (Zn/Fe). Zn/Fe preferentially releases the antioxidant element Zn in the early degradation due to Zn–Fe galvanic coupling corrosion. It facilitates the adhesion and proliferation of endothelial cells and mitigates the risk of oxidative stress. The degradation rate of Zn/Fe was about 1.6 times that of Fe after 56 days of implantation in the common carotid artery of rats, with a 36.1% reduction in lumen loss rate, demonstrating favorable in vivo biocompatibility. These findings provide valuable insights for the development of novel functionalized Fe-based scaffold medical devices.

Institutions

Publication Details

Journal
Regenerative Biomaterials
Published
2025-11-07
DOI
https://doi.org/10.1093/rb/rbaf112
Primary Topic
Electrospun Nanofibers in Biomedical Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Zn ion-implanted absorbable Fe for improved cytocompatibility and mitigated neointimal hyperplasia

Regenerative Biomaterials
Electrospun Nanofibers in Biomedical Applications
article

Zn ion-implanted absorbable Fe for improved cytocompatibility and mitigated neointimal hyperplasia

article en

Abstract

Abstract Ultrathin strut Fe-based scaffolds have made significant progress in the field of vascular interventional devices, but the issues of slow degradation and insufficient biocompatibility at the cell/material interface remain unresolved. This study prepared a functionalized surface on Fe by Zn ion implantation (Zn/Fe). Zn/Fe preferentially releases the antioxidant element Zn in the early degradation due to Zn–Fe galvanic coupling corrosion. It facilitates the adhesion and proliferation of endothelial cells and mitigates the risk of oxidative stress. The degradation rate of Zn/Fe was about 1.6 times that of Fe after 56 days of implantation in the common carotid artery of rats, with a 36.1% reduction in lumen loss rate, demonstrating favorable in vivo biocompatibility. These findings provide valuable insights for the development of novel functionalized Fe-based scaffold medical devices.

Regenerative BiomaterialsVol. 13
Zhejiang International Studies University (CN), Capital Medical University (CN), Beijing Institute of Neurosurgery (CN), Beihang University (CN)
National Natural Science Foundation of China, Beijing Nova Program
Openalex Percentile: Top 52%
Electrospun Nanofibers in Biomedical Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Zn ion-implanted absorbable Fe for improved cytocompatibility and mitigated neointimal hyperplasia · Regenerative Biomaterials (2025) | TGRS Research Map | TGRS