METHOD DEVELOPMENT AND VALIDATION FOR ESTIMATION OF TOLTERODINE IN TABLET DOSAGE FORM BY RP-HPLC

A simple, precise, and robust reverse phase high-performance liquid chromatography (RP-HPLC) method was developed and validated for the quantitative estimation of Tolterodine in tablet dosage forms. Chromatographic separation was achieved on a YMC Triart C18 column (250 × 4.6 mm, 5.0 µm) using a mobile phase of 10 mM ammonium bicarbonate in water and acetonitrile (70:30, v/v) at a flow rate of 0.7 mL/min with detection at 280 nm. The method was validated as per ICH Q2(R1) guidelines, evaluating specificity, linearity, accuracy, precision, robustness, system suitability, limit of detection (LOD), and limit of quantification (LOQ). Calibration was linear across the 2–12 µg/mL range with a regression coefficient (R²) of 0.999. Recovery ranged from 98–102%, and intra/inter-day precision studies showed %RSD values below 2%. The method demonstrated consistent results under minor variations in flow rate and column temperature, confirming robustness. The validated method is rapid, sensitive, accurate, and suitable for routine quality control and stability analysis of Tolterodine in pharmaceutical dosage forms Keywords: Tolteridone, RP- HPC, Validation, ICH Guidelines

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-11-05
DOI
https://doi.org/10.5281/zenodo.17556107
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

METHOD DEVELOPMENT AND VALIDATION FOR ESTIMATION OF TOLTERODINE IN TABLET DOSAGE FORM BY RP-HPLC

Zenodo (CERN European Organization for Nuclear Research)
Analytical Methods in Pharmaceuticals
article

METHOD DEVELOPMENT AND VALIDATION FOR ESTIMATION OF TOLTERODINE IN TABLET DOSAGE FORM BY RP-HPLC

article en

Abstract

A simple, precise, and robust reverse phase high-performance liquid chromatography (RP-HPLC) method was developed and validated for the quantitative estimation of Tolterodine in tablet dosage forms. Chromatographic separation was achieved on a YMC Triart C18 column (250 × 4.6 mm, 5.0 µm) using a mobile phase of 10 mM ammonium bicarbonate in water and acetonitrile (70:30, v/v) at a flow rate of 0.7 mL/min with detection at 280 nm. The method was validated as per ICH Q2(R1) guidelines, evaluating specificity, linearity, accuracy, precision, robustness, system suitability, limit of detection (LOD), and limit of quantification (LOQ). Calibration was linear across the 2–12 µg/mL range with a regression coefficient (R²) of 0.999. Recovery ranged from 98–102%, and intra/inter-day precision studies showed %RSD values below 2%. The method demonstrated consistent results under minor variations in flow rate and column temperature, confirming robustness. The validated method is rapid, sensitive, accurate, and suitable for routine quality control and stability analysis of Tolterodine in pharmaceutical dosage forms Keywords: Tolteridone, RP- HPC, Validation, ICH Guidelines

Zenodo (CERN European Organization for Nuclear Research)
Kanya Maha Vidyalaya (IN)
Openalex Percentile: Top 47%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.