Layout optimization and comparison of a Carbon-ion gantry based on different mechanical structures

Carbon ion therapy is one of the most effective radiotherapy methods for cancer treatment, offering superior dose conformality compared to conventional radiation therapies. The combination of carbon ion treatment with a gantry further enhances treatment effectiveness and safety. When designing a gantry, the magnet aperture must consider both the beam envelope and the beam position errors all along the gantry beamline. These errors may arise from magnetic field errors, imperfect magnet alignment, construction inaccuracies and mechanical design choices. A well-matched optics guarantees a low beam envelope; however, this does not always correspond to an optimization of the space occupied by the beam after introducing error sources and related corrections. Thus, a novel methodology that integrates optics and mechanical studies has been developed. By combining mechanical deformation analyses and optics correction optimization algorithms, this study provides a comprehensive solution for the HITRIplus carbon ion gantry design. A detailed analysis of the impact of two different design options for the supporting system of the SC magnets is provided.

Publication Details

Journal
JACOW
Published
2025-11-05
DOI
https://doi.org/10.18429/jacow-ipac2025-wepm003
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Layout optimization and comparison of a Carbon-ion gantry based on different mechanical structures

JACOW
Radiation Therapy and Dosimetry
article

Layout optimization and comparison of a Carbon-ion gantry based on different mechanical structures

article en

Abstract

Carbon ion therapy is one of the most effective radiotherapy methods for cancer treatment, offering superior dose conformality compared to conventional radiation therapies. The combination of carbon ion treatment with a gantry further enhances treatment effectiveness and safety. When designing a gantry, the magnet aperture must consider both the beam envelope and the beam position errors all along the gantry beamline. These errors may arise from magnetic field errors, imperfect magnet alignment, construction inaccuracies and mechanical design choices. A well-matched optics guarantees a low beam envelope; however, this does not always correspond to an optimization of the space occupied by the beam after introducing error sources and related corrections. Thus, a novel methodology that integrates optics and mechanical studies has been developed. By combining mechanical deformation analyses and optics correction optimization algorithms, this study provides a comprehensive solution for the HITRIplus carbon ion gantry design. A detailed analysis of the impact of two different design options for the supporting system of the SC magnets is provided.

JACOW
Openalex Percentile: Top 33%
Radiation Therapy and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.